Technical specifications
13.3 Technical specifications for POM
SIPLUS HCS4200
132
Operating Instructions, 11/2015, A5E35066204A/RS-AA/002
Power Electronics:
Control version / of heat emitters
Half-wave control
Half-wave control and soft start
Number of outputs / for heating power
16
12
Number of heat emitters / per output / maximum 1
Output voltage / at output / for heating power
230 V
277 V
Power capacity / per output
100 W ... 1 449 W
100 W ... 4 432 W
Output current / at output / for heating power /
Rated value
6.3 A
16 A
Design of short-circuit protection / for heating
power / per output
Safety fuse 6.3 A
Fuse 16 A
Melting I2t value
57 A²·s
68 A²·s
Design of the overvoltage protection
Transil Diode
Galvanic isolation / between the outputs
No
Type of electrical connection / at output / for
heating and fan
Connector, 8-pin Connector, 6-pin
•
Type of connectable conductor cross-section
/ for heating and fan / solid
1x (0.2 ... 10 mm²)
•
Type of connectable conductor cross-section
/ for heating and fan / finely stranded / with
core end processing
1x (0,25 ... 6 mm²)
•
Type of connectable conductor cross-
sections / at AWG conductors / stranded
1x (24 ... 8)
Communication:
Design of the interface
system interface
Display:
Number of status displays
19
15
Display version / as status display by LED
LED green = ready, LED yellow = heating on/off, LED red = error
display, LED red = error for each channel
Auxiliary circuit:
Design of the power supply
Power supply via rack
Active power consumption / maximum
1 W
Protective and monitoring functions:
Product function / Temperature monitoring
Yes
Type of the temperature monitoring
NTC thermistor
Diagnostics function
Voltage diagnostics
•
Tripped fuse
Yes
•
Cable break
Yes
•
Heat emitter failure
Yes