Controller Event Tasks
Commands
8
52 | 66
A6V11144326
Type
Command
Description
Pulse
Sends a pulse command to the selected
Input. This is only applicable for Sintony
input points of type “Serial Coms Input”
Set state to Alarm
Set the input to state Alarm.
Set state to Normal
Set the input to state Normal.
Intrusion
Arm intrusion area
Arms the specified intrusion area.
Disarm intrusion area
Disarms the specified intrusion area.
Isolate input
Isolates input points in alarm mode and
disables them within the specified intrusion
area so that it can be armed for intrusion.
Part Arm Intrusion Area Arm input points in an Intrusion area.
Part Arm B Intrusion
Area
Arm input points B in an Intrusion area.
Clear Sintony Intrusion
area alarm.
Sends command to Sintony panel to clear
the Sintony intrusion area alarm.
Output Point
Unlock
Unsecures the selected output point. Enter
the time for which you want the door to be
unlocked into the Duration field, using the
format HH:MM:SS.
Lock
Secures the selected output point. Enter
the time for which you want the door to be
locked into the Duration field, using the
format HH:MM:SS.
Toggle
Reverses the current status of the output
point.
Slow Pulse
Causes the output point to emit a slow
pulse behaviour, depending on the point
type. For example, a strobe light attached
to a door controller would flash at a
relatively slow rate.
Enter the time for which you want the
output to slow pulse into the Duration field,
using the format HH:MM:SS.
Fast Pulse
Causes the output point to emit fast pulse
behaviour, depending on the point type.
For example, a siren attached to a door
controller would sound at rela-tively fast
repeated intervals.
Enter the time for which you want the
output to fast pulse into the Duration field,
using the format HH:MM:SS.
Single Pulse
Causes the output point to emit a single
pulse, depending on the point type.
Return to Time Schedule
Control
The output will return to normal Time
Schedule control.
Summary of Contents for SiPass integrated