Firmware Configuration Tools
ACC and FLN Field Service Network Tool
1
8 | 38
A6V11164550
1.2.3
Network Discovery for Access Controllers
It is possible to configure Access Controllers via Ethernet, without prior
configuration of any settings.
The ACC and FLN Field Service Tool uses UDP Broadcasts to identify ACC
controllers that have their Quickstart feature enabled. Once identified, the network
parameters can be configured such that the controller can now connect to the
SiPass server.
CAVEAT ! This can only work in the local Ethernet segment as UDP Broadcasts
cannot cross routers.
Make sure that the SiPass server is running before using the Network Discovery
tool.
Make sure Ethernet cable is plugged in, and the PC/laptop is on the same physical
Ether network as the ACCs that are to be discovered.
Click the Network Search button
–
a list of not yet configured ACCs should appear.
Select one unit, and examine its network settings.
If the tool is being run from the SiPass server, select the correct network interface
and then use the Copy As Host, Copy Subnet and Copy Gateway settings.
If the tool is just being run from a laptop, configure the host network settings in the
Default Controller Network Configuration
pane.
Choose a unique IP address for the controller (consult with your IT if required).
Finally, click the Download Configuration button, and the controller is configured.
See below for an example screen shot showing a range of controllers, including
one ACC-G2 being configured to operate on the local network.
Note: the IP addresses are for example only, be sure to use values applicable to
your network.