
Access Controllers
ACC-AP
2
26 | 38
A6V11164550
2.3.8
Platform Upgrade via Firmware Download
Before attempting to perform a platform upgrade via Firmware download, ensure
that you are using:
●
Platform version V1.0.6 (or later) and
●
AP Application Version V2.75.11 (or later)
If using an earlier platform version, you must perform the platform upgrade via SD-
Card to upgrade to platform version V1.0.6 or later. The SD-Card for platform
V1.0.6 will also contain AP application version V2.75.11.
For more details see the
Common Firmware Update Procedure [➙
11] section.
2.3.9
LED Indications
2.3.9.1
During SD Card Update
LED Indication
Description
RED
–
On
Siemens bootstrap and u-boot running
ORANGE
–
Flashing
NAND Flash update is in progress
GREEN
–
Flashing
NAND Flash update finished, SD card shutting down
ORANGE
–
On
●
SD-Card shut down. Count to 7, remove power, remove SD
card, restart.
●
After SD-Card removal
–
ACC-Application running
RED - Flashing
Update failed. Retry SD-Card update
2.3.9.2
During ACC-Application (Run-Time)
LED Indication
Description
RED
Controller is starting up
ORANGE
Application running
GREEN
Application running, connected with SiPass integrated
OFF (Dark)
Application not running. (This can occur during a Firmware
upgrade.)