5 External interface
SINAUT MD741-1
66
C79000-G8976-C236-05
User name / Password
Enter here the username and the password that authorise you to use the DynDNS
service. Your DynDNS provider will give you this information.
Host name of the DynDNS server
Here enter the hostname that you have agreed with your DynDNS provider for the
SINAUT MD741-1, e.g. myMD741.dyndns.org.
Factory settings
The factory settings for the SINAUT MD741-1 are as follows:
Log this device on at a DynDNS server
No (switched off)
Username
guest
Password
guest
Host name
myname.dyndns.org
5.6
SRS – Siemens Remote Service
Note
Using the services provided by the "SIMATIC Remote Support Services", remote
access to machines and plants is available.
To use the services, additional service agreements are necessary and certain
constraints must be kept to. If you are interested in the Siemens Remote Service,
speak to your local Siemens contact.
If the Siemens Remote Service is activated, the SINAUT MD741-1 transfers its
external IP address assigned by the EDGE/GPRS service to a selectable
destination server. This transfer is made using the secure HTTPS protocol.
The procedure is comparable with the DynDNS service and requires suitable
access to the server.