SINAUT MD741-1
25
C79000-G8976-C236-04
Configuration
3
Configuration of the router and firewall functions is carried out locally or remotely
via the Web-based administration interface of the SINAUT MD741-1.
Remote configuration
Remote configuration via HTTPS or CSD access is only possible if the SINAUT
MD741-1 is configured for remote access. In this case proceed exactly as
described in Chapter 8.
Configuration via the local interface
The preconditions for configuration via the local interface are:
●
The computer (Admin PC) that you use to carry out configuration must be
either connected directly to the Ethernet jack of the SINAUT MD741-1 via a
network cable or it must have direct access to the SINAUT MD741-1 via the
local network.
●
The network adapter of the computer (Admin PC) that you use to carry out
configuration must have the following TCP/IP configuration:
IP address:
192.168.1.2
Subnet mask:
255.255.255.0
Instead of the IP address
192.168.1.2
you can also use other IP addresses
from the
range 192.169.1.x
.
●
If you also wish to use the Admin PC to access the external network via the
SINAUT MD741-1, the following additional settings are necessary:
Standard gateway:
192.168.1.1
Preferred DNS server:
Address of the domain name server