3-27
S7-200 Programmable Controller, CPU 210
C79000-G7076-C235-01
Network 11
LAD
STL
NETWORK
LDW=
MW1, +1
A
M4.0
LDW=
MW1, +2
A
M4.1
LDW=
MW1, +3
A
M4.2
LDW=
MW1, +6
A
M4.5
LDW=
MW1, +7
A
M4.6
LDW=
MW1, +8
A
M4.7
OLD
AN
I0.2
S
M0.0, 1
If the step counter equals a particular
value and the corresponding bit pattern
is on, set the LED bit if the system is
not armed.
M4.0
I0.2
/
M0.0
S
1
MW1
==I
+1
M4.1
MW1
==I
+2
M4.2
MW1
==I
+3
M4.5
MW1
==I
+6
M4.6
MW1
==I
+7
M4.7
MW1
==I
+8
Figure 3-27 Control Logic for Controlling the Blink Pattern
LAD
STL
Network 12
NETWORK
LDW>=
MW1, +10
LD
I0.0
A
I0.1
OLD
MOVW
+0, MW1
If the step counter equals 10 and both Zone 1 and
Zone 2 are closed, then reset the step counter to 0.
MW1
>=I
+10
MOV_W
EN
IN
OUT
+0
MW1
I0.0
I0.1
Figure 3-28 Control Logic for Resetting the Counter