![Siemens SIMATIC PRO Extension Unit 12](http://html.mh-extra.com/html/siemens/simatic-pro-extension-unit-12-f-pn-advanced/simatic-pro-extension-unit-12-f-pn-advanced_operating-instructions-manual_1265372070.webp)
Configuring Extension Unit PROFINET and PROFIsafe
4.6 Configuring standard operator controls
Extension Units KPxx
70
Operating Instructions, 05/2019, A5E43600360-AC
4.6
Configuring standard operator controls
The following procedure describes the configuration of a standard operator control using an
illuminated pushbutton as an example. The other standard operator controls are configured
in the same way.
Requirement
●
The necessary software is installed.
●
You have opened a project with Extension Unit.
●
The Device view is open.
Procedure
1.
Select the required Extension Unit in the Device view.
2.
Select the required operator control in the catalog tree.
3.
Drag the required operator control to the preferred mounting position. The mounting
position must match the physical mounting position of the operator control.
4.