Mounting and connecting the Extension Unit
3.2 Preparing the installation
Extension Units KPxx
38
Operating Instructions, 05/2019, A5E43600360-AC
Result
You need the following connecting cables, see "Rear" section in section
"Advanced operator controls and interfaces (Page 17)":
Number of slots in
between
required cable lengths for skipping
Article number
Total
quantity
0
50 mm connecting cable
6AV2185-8AW05-0AA0 1
1
105 mm connecting cable
6AV2185-8AW10-0AA0 1
4
300 mm connecting cable
6AV2185-8AW30-0AA0 1
-
500 mm connecting cable
6AV2185-8AW50-0AA0 0
3.2.5
Preassemble the short-stroke adapter
With some Advanced operator controls, a short-stroke adapter shortens the path of the lens
assemblies. Operation appears more precise and the reaction more immediate.
Preassemble the short-stroke adapter on the operator control.
Procedure
1.
Install the spring to the left of the short-stroke adapter as shown.
2.
Insert the short-stroke adapter into the operator control from behind. The short-stroke
adapter has a large and a small groove as locking element.
Make sure that the large groove on the short-stroke adapter engages in the large recess
on the operator control as marked.
3.
Insert the short-stroke adapter into the operator control until it clicks into place. The short-
stroke adapter must grip the operator control evenly on all sides.