Configuration
3.3 Making general settings
SINEMA Remote Connect - Client
Operating Instructions, 11/2017, C79000-G8976-C395-04
23
Smartcard setting
To log on with the Smartcard, specify the path of the library file pks11-dll (32-bit).
Routing settings
●
Insert default route
–
Disabled (default setting)
The routes of the SINEMA RC Server are adopted in the routing table of the client PC.
Other settings are not necessary.
–
Enabled
Enable the setting only when the connection establishment from the SINEMA RC
client to the server takes several minutes. When enabled three routes are entered in
the routing table of the client PC that divert the entire data traffic of the client PC to the
SINEMA RC Server. This means for example that you can no longer call up mails from
a mail server. In this case, in the routing table you can create a route to the destination
network of the mail server. To create a route, you require administrator rights.
The route is added via the command line with the following command:
route
add <destination network> mask <subnet mask> <gateway> metric <path costs>
Example:
Destination network of the mail server: 192.168.172.0
Client PC is connected to the destination network:
route add 192.168.172.0 mask
255.255.255.0 metric 2
Destination network is reachable via a gateway:
route add 192.168.172.0 mask
255.255.255.0 10.168.2.20 metric 2