Communication Ports
4.3 Available Modules
State
Description
Green (Solid)
Link detected
Yellow (Solid)
Link detected and PoE established
Blinking
Link activity
Off
No link detected
Specifications
For specifications on the available PoE ports, refer to
4.3
Available Modules
A variety of modules are available for use with the RUGGEDCOM RST2228P.
For more information, refer to the
support.industry.siemens.com/cs/us/en/view/109752858]
for the RUGGEDCOM
RST2228P.
4.4
Installing/Removing Modules
Upon installing a new media module in the device, all features associated with
the module are available in RUGGEDCOM ROS. For more information, refer to the
RUGGEDCOM ROS Configuration Manual
for the device.
Once a media module is removed, all the features associated with the module are
hidden or disabled in RUGGEDCOM ROS.
CAUTION
Contamination hazard – risk of equipment damage.
Prevent the ingress of water, dirts and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty and open ports are
protected with plugs or covers.
Removing a Module
To remove a media module, do the following:
1. Make sure power to the device has been disconnected and wait approximately
two minutes for any remaining energy to dissipate.
2. [Optional] If the device is installed in a rack, remove it from the rack.
3. Loosen the screw(s) that secure the module.
RUGGEDCOM RST2228P
Installation Manual, 07/2021, C79000-G8976-1403-13
35