Installing the Device

2.5 Connecting Power

2. Connect a failsafe device to the terminal block.

5

1

4

4

5

3

2

3

     1    

Pluggable Terminal Block

     2    

Screw-Type Terminal Block

     3    

Normally Open Terminal

     4    

Common Terminal

     5    

Normally Closed Terminal

Figure 2.5

Failsafe Alarm Relay Wiring

2.5

Connecting Power

The RUGGEDCOM RST2228P supports dual redundant AC and/or DC power supplies

that can be installed in any combination.
The RUGGEDCOM RST2228P can be equipped with either a screw-type or pluggable

terminal block, which provides power to both power supplies. The screw-type

terminal block is installed using Phillips screws and compression plates, allowing

either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for

secure, reliable connections under severe shock or vibration.

DANGER

Electrocution hazard – risk of serious personal injury or death

The device may have two power supplies equipped, which may be connected to

separate power sources. Make sure all power sources are off before servicing the

power supply terminals.

CAUTION

Electrical hazard – risk of damage to equipment

Do not exceed the power supply voltage ratings for each power supply input. For

example, if PS1 is a low DC power supply, do not connect the PS1 terminals to a high

AC/DC power source.

RUGGEDCOM RST2228P

Installation Manual, 07/2021, C79000-G8976-1403-13

15

Summary of Contents for SIMATIC NET RUGGEDCOM RST2228P

Page 1: ...Edition 07 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RST2228P https www siemens com ...

Page 2: ...d Ethernet Switches RUGGEDCOM RST2228P Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07 2021 C79000 G8976 1403 13 ...

Page 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Page 4: ...5 3 Supported Fiber Optic Cables 8 2 Installing the Device 9 2 1 General Procedure 10 2 2 Unpacking the Device 11 2 3 Mounting the Device 11 2 3 1 Mounting the Device to a Rack 11 2 3 2 Mounting the Device to a Panel 12 2 4 Connecting the Failsafe Alarm Relay 14 2 5 Connecting Power 15 2 5 1 Connecting High AC DC Power 16 2 5 2 Connecting Low DC Power 18 2 5 3 Connecting External PoE Power 21 2 5 ...

Page 5: ...Relay Specifications 39 5 5 Supported Networking Standards 39 5 6 Operating Environment 39 5 7 Mechanical Specifications 40 5 8 Dimension Drawings 40 6 Certification 43 6 1 Approvals 43 6 1 1 CSA 43 6 1 2 European Union EU 43 6 1 3 TÜV SÜD 44 6 1 4 FDA CDRH 44 6 1 5 FCC 45 6 1 6 ISED 45 6 1 7 ISO 45 6 1 8 RoHS 45 6 1 9 Other Approvals 46 6 2 EMC and Environmental Type Tests 46 iv RUGGEDCOM RST2228...

Page 6: ...om cs ww en view 109752858 RUGGEDCOM SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Time Synchronization Capabilities of RUGGEDCOM Devices https support industry siemens com cs ww en view 109780448 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online ...

Page 7: ...conforming goods or services whether claims of the Customer are based in contract including fundamental breach in tort including negligence and strict liability or otherwise For warranty details visit https www siemens com or contact a Siemens customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networkin...

Page 8: ...ll the Industry Online Support app by Siemens AG on any Android Apple iOS or Windows mobile device and be able to Access Siemens extensive library of support documentation including FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and t...

Page 9: ...Preface Contacting Siemens viii RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 10: ...EDCOM ROS which provides advanced Layer 2 networking functions and advanced cyber security features 1 1 Feature Highlights Power over Ethernet PoE Supports up to 24 PoE ports with data transfer rates of 10 100 1000 Mbit s Supports 4 pair or 60 W port Supports up to 120 W of PoE power module e g two 60 W ports or four 30 W ports Supports up to maximum 500 W system Data and power over a single Ether...

Page 11: ...Reliability in Harsh Environments Immunity to EMI and heavy electrical surges Zero Packet Loss Technology Supports Siemens FastConnect RJ45 Cabling System 40 to 85 C 40 to 185 F operating temperature fan less Conformal coated printed circuit boards optional 1 2 Description The RUGGEDCOM RST2228P features various ports controls and indicator LEDs for connecting configuring and troubleshooting the d...

Page 12: ...3 4 5 6 7 8 1 Status Panel 2 ACO Button 3 CLP Port 4 USB Console Port 5 PoE Power and Failsafe Alarm Relay Terminal Block 6 Power Terminal Block 7 SFP SFP Transceiver Sockets 8 Media Modules 9 Chassis Ground Terminal Figure 1 1 RUGGEDCOM RST2228P Front Panel Orientation RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 3 ...

Page 13: ...r Sockets 8 Media Modules 9 Chassis Ground Terminal Figure 1 2 RUGGEDCOM RST2228P Rear Panel Orientation Key Features Status Panel The status panel displays the real time status of the device Six module slot locators indicate the physical location of each media module in relation to the available chassis slots Module ports are numbered from left to right when installed in the chassis A dedicated L...

Page 14: ... PoE power source is not supplying power to the device USB Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about connecting to the device via the serial console port refer to Connecting to the Device Page 27 Alarm Indicator LED The alarm indicator LED illuminates when an alarm condition exists Pressing the ...

Page 15: ...nstalling modules and terminal blocks Torx T10 screwdriver For removing or installing modules Phillips screwdriver For removing or installing terminal blocks 8 x M6 or 10 32 screws For mounting the device to a panel 8 x M6 or 10 32 screws For mounting the device to a rack Braided or equivalent ground wire For grounding the device to safety Earth 1 4 Decommissioning and Disposal Proper decommission...

Page 16: ...e IEEE 802 3ab Gigabit Ethernet standard defines 1000 Mbit s Ethernet communications over distances of up to 100 m 328 ft using all 4 pairs in category 5 or higher balanced unshielded twisted pair cabling For wiring guidelines system designers and integrators should refer to the Telecommunications Industry Association TIA TIA EIA 568 A wiring standard that characterizes minimum cabling performance...

Page 17: ...oupling Shielded screened cabling can be used when required Care should be taken to avoid the creation of ground loops with shielded cabling 1 5 3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 5...

Page 18: ...er than those specified herein may result in hazardous radiation exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE Pollution Degree This device must be installed in an environment with a m...

Page 19: ...on the device 1 Review the relevant certification information for any regulatory requirements For more information refer to Approvals Page 43 2 Review the Modules Catalog for the device for special installation or regulatory requirements related to the modules installed in the device For more information refer to Related Documents Page v 3 Unpack and inspect the device For more information refer t...

Page 20: ...s from the enclosure As such it is recommended that 2 5 cm 1 in of space be maintained on all open sides of the device to allow for some convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device with ...

Page 21: ...ce is channeled to the enclosure it is recommended that 1 rack unit of space or 44 mm 1 75 in be kept empty above the device This allows a small amount of convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space 3 Secure the adapters to the r...

Page 22: ... the chassis 1 2 1 Mounting Adapter 2 Screw Figure 2 2 Installing the Mounting Adapters 2 Place the device against the panel and align the adapters with the mounting holes 2 1 1 Screw 2 Panel Adapter Figure 2 3 Panel Mounting 3 Secure the adapters to the panel with M6 or 10 32 screws RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 13 ...

Page 23: ...ews and compression plates allowing either bare wire connections or crimped terminal lugs Use M3 5 ring lugs that have short insulated ring terminals with a maximum distance of 5 mm 0 2 in from the ring center to the insulation To connect the failsafe alarm relay do the following 1 Connect the failsafe alarm relay terminal block to the device The terminal block is available as either a screw type ...

Page 24: ...nal block is installed using Phillips screws and compression plates allowing either bare wire connections or crimped terminal lugs Use 6 size ring lugs for secure reliable connections under severe shock or vibration DANGER Electrocution hazard risk of serious personal injury or death The device may have two power supplies equipped which may be connected to separate power sources Make sure all powe...

Page 25: ...plicable local wiring codes and standards 2 5 1 Connecting High AC DC Power To connect a high AC DC power supply to the device do the following DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied cover is always installed over high voltage screw type terminal blocks NOTICE Electrical hazard risk of damage to equipment Do not connect ...

Page 26: ...luggable Terminal Block 2 Screw Type Terminal Block 3 Positive Line L Terminal for PS1 4 Chassis Ground Terminal for PS1 5 Negative Neutral N Terminal for PS1 6 Positive Line L Terminal for PS2 7 Chassis Ground Terminal for PS2 8 Negative Neutral N Terminal for PS2 Figure 2 7 AC Terminal Block Wiring 3 Connect the ground wire to the chassis ground terminal on the terminal block 4 Connect the Neutr...

Page 27: ...4 8 AWG copper cable or cable with a cross section of 1 5 to 6 mm 2 1 1 M3 Screw 2 M3 Ring Lug Figure 2 9 Chassis Ground Connection 2 5 2 Connecting Low DC Power To connect a low DC power supply to the device do the following Note The screw type terminal block is installed using Phillips screws and compression plates allowing either bare wire connections or crimped terminal lugs Use 6 size ring lu...

Page 28: ...pply may occur NOTICE Electrical hazard risk of damage to equipment When connecting the device to a DC power source make sure the source provides only positive voltage 1 Connect the power supply terminal block to the device 1 2 1 Pluggable Terminal Block 2 Screw Type Terminal Block Figure 2 10 Assembling the Power Supply Terminal Block RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 14...

Page 29: ...1 4 Chassis Ground Terminal for PS1 5 Negative Terminal for PS1 6 Positive Terminal for PS2 7 Chassis Ground Terminal for PS2 8 Negative Terminal for PS2 Figure 2 11 DC Terminal Block Wiring 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 For pluggable terminal blocks install the safety cover 1 2 Figure 2 12 Assembling the Safety Cover 20 RUGGEDCO...

Page 30: ...DC output power supply Make sure the PoE power supply has galvanic isolation from high voltage and field wiring Note For IEC 61850 compliance use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m 118 in Otherwise Siemens recommends using the RUGGEDCOM RPS1300 switch mode AC power supply For more information about this power supply refer to https support industry siemens...

Page 31: ... or Euroblock to the terminal 1 2 3 4 3 4 1 Pluggable Terminal Block 2 Screw Type Terminal Block 3 Positive Terminal for PoE 4 Negative Terminal for PoE Figure 2 14 Terminal Block Wiring 2 Connect the positive wire from the RUGGEDCOM RPS1300 or another external power supply to the positive terminal on the terminal block 3 Connect the negative wire from the RUGGEDCOM RPS1300 or another external pow...

Page 32: ...Installing the Device 2 5 4 Wiring Examples Figure 2 15 Single High AC DC Power Supply Figure 2 16 Single Low DC Power Supply RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 23 ...

Page 33: ...Installing the Device 2 5 4 Wiring Examples Figure 2 17 Dual High AC DC Power Supply Figure 2 18 Dual Low DC Power Supply 24 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 34: ...nstalling the Device 2 5 4 Wiring Examples Figure 2 19 High AC DC Power Supply and Low DC Power Supply Figure 2 20 PoE Power Supply RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 25 ...

Page 35: ...Installing the Device 2 5 4 Wiring Examples 26 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 36: ... the slots on the connector where the contacts connect is too short causing the connector pins in the port to lift before a proper connection is made It is determined the minimum slot length must be 5 5 mm 0 216 in 5 5 mm Adjusting the position of the connector in the port either by wiggling or pulling the connector back corrects the issue temporarily but is not recommended It may cause damage to ...

Page 37: ...connecting via the USB Type B console port For more information refer to the RUGGEDCOM ROS Configuration Manual for the device Use the following settings to connect to the port Speed 57600 baud Data Bits 8 Stop Bit 1 Parity None Flow Control Off Terminal ID VT100 Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RST2228P consol...

Page 38: ...ty Do not expose the CLP to large magnetic or static electric fields Do not bend or drop the CLP NOTICE Security hazard risk of unauthorized access and or exploitation Make sure to remove the CLP before decommissioning the device or sending the device to a third party NOTICE Contamination hazard risk of dust and dirt entering the CLP slot When the CLP is not installed make sure the protective cove...

Page 39: ...er into the bottom portion of the CLP port and gently pry the CLP out 1 2 1 CLP 2 Protective cover Figure 3 1 Removing the CLP 2 Insert the protective cover or a new CLP to prevent the ingress of dust and dirt 30 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 40: ...ng the CLP To install the CLP do the following 1 Remove the protective cover from the CLP port 1 2 1 Protective cover 2 CLP Figure 3 2 Installing the CLP 2 Insert the CLP into the CLP port RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 31 ...

Page 41: ...Device Management 3 3 Inserting Removing the CLP 32 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 42: ...upported Modules can be installed in any one of the available slots in the device chassis Module slot locations and port status are indicated on the status panel For more information about the status panel refer to Description Page 2 Use RUGGEDCOM RST2228P to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROS Configuration Manual for the device 0 1 2 3...

Page 43: ... party components 4 2 PoE Ports The RUGGEDCOM RST2228P supports up to twenty four 10 100 1000 Mbps Power over Ethernet PoE ports powered by an external power supply Each port complies with the IEEE 802 3af and IEEE 802 3at standards and features auto sensing and automatic power off when cables are removed The total allowable power budget for all ports is 500 W If the external power supply is less ...

Page 44: ... are available in RUGGEDCOM ROS For more information refer to the RUGGEDCOM ROS Configuration Manual for the device Once a media module is removed all the features associated with the module are hidden or disabled in RUGGEDCOM ROS CAUTION Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that may lead to premature equipment failure Always make sure s...

Page 45: ...dia module do the following 1 Make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate 2 Optional If the device is installed in a rack remove it from the rack 3 Remove the current module from the slot 4 Insert the new module into the slot Figure 4 3 Installing a Module 5 Tighten the screw s to secure the module 6 Optional If neces...

Page 46: ...y Type Minimum Nominal Maximum Maximum Power Consumption b Wire Gage 12 VDC Single 10 5 VDC 12 VDC 15 VDC 77 W 14 24 VDC Single 13 VDC 24 VDC 36 VDC 72 W 14 48 VDC Single 36 VDC 48 VDC 72 VDC 72 W 16 88 VDC 125 250 VDC 300 VDC 77 W 76W HI AC DC 85 VAC c 110 230 VAC 264 VAC c 75 W 75W 18 a Voltage must be measured at the input power terminal b Based on nominal input voltages and 60 W output load c ...

Page 47: ...onds minimum 5 seconds maximum HI AC DC 400 VDC 500 VAC 3 15 A Surge Withstand 1000 0 01 seconds minimum 15 seconds maximum 5 3 PoE Power Supply Specifications The RUGGEDCOM RST2228P adheres to the following power output and IEEE specifications depending on the input voltage supplied to the device CAUTION Electrical hazard risk of damage to the device Do not connect or disconnect the POE power ter...

Page 48: ...C 125 VDC 0 15 A 1 5kVAC 150 VAC 2 A 1 5kVAC 5 5 Supported Networking Standards Parameter 10 Mbps 100 Mbps 1000 Mbps 10000 Mbps Notes IEEE 802 1AB ü ü ü ü Link Layer Discovery Protocol LLDP IEEE 802 1D ü ü ü ü MAC bridges IEEE 802 1Q ü ü ü ü VLAN Virtual LAN IEEE 802 1p ü ü ü ü Priority levels IEEE 802 1x ü ü ü ü Port based network access control IEEE 802 3 ü 10Base T IEEE 802 3u ü 100Base TX 100B...

Page 49: ...surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 7 Mechanical Specifications Weight 8 0 kg 18 lbs Ingress Protection IP3x for pluggable connectors Enclosure Galvanized steel 5 8 Dimension Drawings Note All dimensions are in millimeters un...

Page 50: ...Technical Specifications 5 8 Dimension Drawings 339 4 43 6 337 0 446 0 22 5 Figure 5 1 Overall Dimensions RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 41 ...

Page 51: ... 462 2 31 6 23 5 314 0 43 6 285 2 23 5 11 8 297 0 273 5 Figure 5 2 Rack Mount Dimensions 3 5 6 8 462 2 31 6 23 5 43 6 285 2 23 5 11 8 297 0 273 5 314 0 Figure 5 3 Panel Mount Dimensions 42 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 52: ...Association CSA standards under certificate 16 70068356 CAN CSA C22 2 No 62368 1 Information Technology Equipment Safety Part 1 General Requirements Bi National Standard with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements The device is marked with a CSA symbol that indicates compliance with both Canadian and U S requirements C US 6 1 2 European Union EU T...

Page 53: ...Technology Equipment Radio disturbance characteristics Limits and methods of measurement EN 50581 Technical Documentation for the Assessment of Electrical and Electronic Products with Respect to the Restriction of Hazardous Substances The device is marked with a CE marking and can be used throughout the European community A copy of the CE Declaration of Conformity is available from Siemens AG For ...

Page 54: ...TICE Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device 6 1 6 ISED This device is declared by Siemens AG to meet the requirements of the following ISED Innovation Science and Economic Development Canada standard CAN ICES 3 A NMB 3 A 6 1 7 ISO This device was designed and manufactured using a certified ISO I...

Page 55: ... and Environmental Type Tests The RUGGEDCOM RST2228P has passed the following EMC and environmental tests EMC Type Test for IEC 61850 3 Note In the case of an all fiber port configuration this product meets all Class 2 requirements Otherwise all Class 1 requirements are met for copper ports and mixed fiber copper ports If the unit contains copper ports the IEC 61850 3 and IEEE 1613 conformance is ...

Page 56: ... IEC 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclosure Ports 100 A m for 3 min 1000 A m for 1 s 5 IEC 61000 4 10 Damped Oscillating Magnetic Field Enclosure Ports 100 A m for 1 s 100 kHz and 1 MHz 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 30 for 1 period 60 for 50 periods 100 for 5 periods 100 for 50 periods Signal Ports 30 V for 60 ...

Page 57: ...sts per IEEE 1613 Description Test Levels Severity Levels Enclosure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure Ports 35 V m 80 modulation Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Fast Transient Earth Ground Ports 4 kV Signal Ports 2 5 kV common mode DC Power Ports 2 5 kV common and 1 0 kV Differential Mode Oscillatory AC Power Ports 2 5 kV common and 1 0 k...

Page 58: ...umidity Damp Heat Cyclic Test Db 93 upper temperature 97 lower temperature 55 C 131 F 6 Cycles IEC 60068 2 78 Humidity Damp Heat Steady State Test Cab 10 days 55 C 131 F and 93 Relative Humidity IEC 60255 21 1 Vibration Level 2 2 g 10 to 150 Hz Class 2 Shock Level 2 30 g 11 mS Class 2 IEC 60255 21 2 Bump Level 1 10 g 16 mS Class 1 IEC 60255 21 3 Seismic Method A Class 2 Class 2 IEC 60529 Ingress P...

Page 59: ...Certification 6 2 EMC and Environmental Type Tests 50 RUGGEDCOM RST2228P Installation Manual 07 2021 C79000 G8976 1403 13 ...

Page 60: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Reviews: