Installing the Device
2.5.2 Connecting Low DC Power
NOTICE
Electrical hazard – risk of damage to equipment.
Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
Damage to the power supply may occur.
NOTICE
Electrical hazard – risk of damage to equipment.
When connecting the device to a DC power source, make sure the source provides
only positive voltage.
1. Connect the power supply terminal block to the device.
1
2
1
Pluggable Terminal Block
2
Screw-Type Terminal Block
Figure 2.10
Assembling the Power Supply Terminal Block
RUGGEDCOM RST2228P
Installation Manual, 07/2021, C79000-G8976-1403-13
19