SIMATIC IPC647E
Operating Instructions, 11/2018, A5E45589180-AA
141
Technical specifications
8
8.1
Applicability of technical specifications
Note
The following technical specifications only apply under the following conditions:
•
The device is in good working order.
•
The fan cover and filter pad are installed.
•
The device is closed.
8.2
General technical specifications
See the note in "Applicability of technical specifications (Page 141)".
Article number
6AG4112-3...-.... (for details, refer to the ordering documentation)
Dimensions
481.4 x 88.1 x 446.6 (W × H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawing of the device
(Page 155)".
Weight
10 up to 14 kg; depending on the equipment
Supply voltage (V
N
)
Single power supply: 100 V AC to 240 V AC (-15%; +10%)
Redundant power supply: 2 × 100 V AC to 240 V AC (-15%; +10%)
Input current
Single power supply:
•
Continuous current at 100 V: ≤ 6 A
•
Continuous current at 230 V: ≤ 3 A
•
At startup ≤ 80
A for 3.6 ms
Redundant power supply:
•
Continuous current at 100 V: ≤ 5 A
•
Continuous
current at 230 V: ≤ 2.5 A
•
at startup ≤ 210 A for 1.65
ms for each module
Information on the dimensioning of the fuses in the higher-level plant circuits
A fuse, which is designed for a tripping current of typical 6.3 A, is integrated in the
power supply of the IPC. Pulse current are also taken into consideration by the "time
lag" type. In the case of fault, this fuse ensure the correct separation of the device
from the power supply.
It is recommended to use a fuse of at least 6.3 A for the protection of the higher-level
power supply circuit in addition to the power requirement of the additional devices
that are also supplied through this circuit. The tripping characteristic of the higher-
level protection must hereby take into consideration the starting currents of the IPC
and those of the other devices.