Installing and connecting the device
3.1 Preparing for installation
SIMATIC IPC377E
Operating Instructions, 2017/05, A5E40965249-AA
25
●
Vertical installation in upright format, display turned through ±90 ° compared with the
standard position
For vertical installation in upright format, the following ambient temperatures are
permitted:
Maximum ambient tem-
perature at the device
Comment
40 °C
The device must be installed in a fire protection enclosure (see
"General safety instructions (Page 15)").
3.1.4
Preparing the mounting cutout
Note
Stability of the mounting cutout
The material in the area of the mounting cutout must provide sufficient strength to guarantee
the enduring and safe mounting of the HMI device.
To achieve the degrees of protection described below, it must be ensured that deformation
of the material cannot occur due to the force of the mounting clips or operation of the device.
Degrees of protection
The degrees of protection of the HMI device can only be guaranteed if the following
requirements are met:
●
Material thickness at the mounting cutout for IP65 degree of protection, or for
enclosure type 4X/type 12 (indoor use only): 2 mm to 6 mm
●
Permissible deviation from plane at the mounting cutout:
≤
0.5 mm
This condition must be fulfilled for the mounted HMI device.
●
Permissible surface roughness in the area of the seal: ≤
120 µm (R
z
120)
Summary of Contents for SIMATIC IPC377E
Page 4: ...Preface SIMATIC IPC377E 4 Operating Instructions 2017 05 A5E40965249 AA ...
Page 8: ...Table of contents SIMATIC IPC377E 8 Operating Instructions 2017 05 A5E40965249 AA ...
Page 112: ...List of abbreviations SIMATIC IPC377E 112 Operating Instructions 2017 05 A5E40965249 AA ...
Page 124: ...Index SIMATIC IPC377E 124 Operating Instructions 2017 05 A5E40965249 AA ...