Installing and connecting the device
3.1 Preparing for installation
SIMATIC IPC377E
24
Operating Instructions, 2017/05, A5E40965249-AA
3.1.3
Permitted mounting positions
The device may be mounted in the following positions:
●
Standard position: Vertical installation in horizontal format
For vertical installation in horizontal format, the following ambient temperatures are
permitted:
Maximum ambient tem-
perature at the device
Comment
40 °C
The device enclosure fulfills the requirement of a fire protection enclo-
sure.
●
Inclined installation in horizontal format with a vertical inclination of maximum ±45 °
For inclined installation in horizontal format, the following ambient temperatures are
permitted:
Maximum ambient tem-
perature at the device
Comment
40 °C
The device enclosure fulfills the requirement of a fire protection enclo-
sure.