Wiring
Distributed I/O Device ET 200R
4–6
(4)J31069-D0427-U001-A2-7618
Pins
Socket
View of the contact side X01, X02 ET 200R
SKÜ 1
Profibus A
Profibus B
+24V (+US1)
0V (-US1)
9
10
11
6
4
1
14
SKÜ 2
Apply shield to plug
connector housing
+24V (+US2)
0V (-US2)
KSR 1
KSR 2
3
2
12
17
13
5
7
8
15
16
Signal Name
see
remark
Apply shield to plug
connector housing
+24V (+US1)
+24V (+US2)
0V (-US1)
9
10
11
6
4
1
3
Profibus B
Profibus A
SKÜ 2
SKÜ 1
0V (-US2)
KSR 1
KSR 2
2
12
17
13
14
5
7
8
15
16
Signal Name
see
remark
Details
Remarks
24V DC Logic
24V DC Digital Outputs
24V_GND Logic
Profibus B / galvanical isolated
Profibus A / galvanical isolated
Digital Input resp. SKÜ_1
24V_GND Digital Outputs
KSR_1
KSR_2
Pin 13+14 : see details
not used
not used
not used
not used
not used
Digital Input resp. SKÜ_2
Handling module :up to ES 01 not connected; from ES 02 wired.
Welding
module
:up to ES 02 not connected; from ES 03 wired.
12
13
14
17
15
16
11
10
9
1
8
7
5
6
4
3
2
12
13
14
17
15
16
11
10
9
1
8
7
5
6
4
3
2
Figure 4-3
Allocation of plugs X01/X02
4.2.3
Plug connectors for the digital inputs and outputs
The digital inputs and outputs are connected to the 5-pin round socket (M12) on the
front of the ET 200R. Another method is to use the 5-pin round coupling plug (M12)
or Y connection pieces for the connection.
Mounting
Using light pressure press the actuator/sensor connector (M12) into the socket (X0
to X7) in the housing. Snap in the mechanical guide of the socket and hand-tighten
the plug connector screw connection.
Cover unused sockets with a dummy cap.
To remove proceed in reverse order.
Wiring coupling plug M12
You will need the following to connect the digital inputs/outputs:
•
one 5-pin, coupling plug connector (M12), can be fabricated,
•
flexible, 3-, 4- or 5-core copper cable with a cross section of
≤
0.75 mm
2