Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
415
●
Message if there is an incorrect login
●
Message when there is a status change in the power supply
●
Message when there is a status change in the error monitoring
●
Message when there is a change in the spanning tree
●
Message if radio channels overlap
●
Message when changes are made to the connection status of WDS
●
Message if a radar signal is received or if there is a status change in the DFS scan.
●
Message if the channel bandwidth changes
●
Message for successful or failed authentication attempts
●
Message if there is a change in the error status (error LED)
●
Message when using iPCF.
These messages can be processed by the clients in different ways:
●
Entry in the logbook of the device
●
Sending the message to the log server of the system
●
Sending an e-mail
●
Sending an SNMP trap
●
Lighting up of the error LED
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
event config {cold-warmstart|linkchange|authentication-failure|
power-change|faultstate-change|stp-change|
overlap-ap|wds|dfs|wlan-general|
wlan-auth-log|ipcf-cycle-time|ipcf-poll-
size|all}{logtable|syslog|email|trap|faults|all}
The parameters have the following meaning:
Parameter
Description
cold-warmstart
Message if there is cold or warm restart
linkchange
Message when there is a status change on a physical interface
authentication-failure
Message if there is an incorrect login
power-change
Message when there is a status change in the power supply
faultstate-change
Message when there is a status change in the error monitoring