Configuration
3.1 System
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
53
Syntax
Call up the command with the following parameters:
cli-console-timeout [seconds(60-600)]
The parameters have the following meaning:
Parameter
Description
Range of values / note
seconds
Time in seconds until automatic logout
after the last entry
60 ... 600
Default: 300
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logout with the
no cli-console-timeout
command.
You display the current timeout setting with the
show cli-console-timeout
command.
3.1.9.7
no cli-console-timeout
Description
With this command, you disable the automatic logout.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout
Result
Automatic logout is disabled.
Further notes
You enable automatic logout with the
cli-console-timeout
command.
You display the current timeout setting with the
show cli-console-timeout
command.