Functions specific to SCALANCE
4.2 Signal recorder
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
89
4.2.4
wlan signal-recorder display (client)
Description
With this command, you configure and start recording with the signal recorder without
specifying a total for the measured values. The measured values are output in the CLI and
logged in files. The files can be downloaded as a zip file using http or tftp. The values are
stored every 10 minutes and overwrite the existing values. The file therefore contains the
values since the last time they were stored.
Note
This command is only available in the client mode.
Requirement
●
The WLAN interface is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (100 - 60000)> display
The parameter has the following meaning:
Parameter
Description
Values or range of values
wlan 0/X
WLAN interface
Enter a valid interface.
ms
The interval in milliseconds (ms) be-
tween acquisition of two measured
values
100 - 60000
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
Result
The recording is configured and will be started. The measured values are output in the CLI
and logged in files. If these files already exist, they will be overwritten.
Use the
wlan signal-recorder <wlan 0/X> stop
command to stop the recording.
During the recording, it is possible that working in the CLI becomes slower.