Functions specific to SCALANCE
4.2 Signal recorder
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
87
Requirement
●
The WLAN interface is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (1 - 60000)> <sample_number(1 - 20000)> start
The parameter has the following meaning:
Parameter
Description
Values or range of values
wlan 0/X
WLAN interface
Enter a valid interface.
ms
The interval in milliseconds (ms) be-
tween acquisition of two measured
values
1 - 60000
sample_number
This parameter specifies how many
measured values will be recorded.
1 - 20000
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
Result
The recording is configured and will be started. The measured values are logged in files. If
these files already exist, they will be overwritten. If the set total number of measured values
is reached, the recording stops automatically. Use the
wlan signal-recorder <wlan 0/X>
stop
command to end the recording early or to end the recording if the number of measured
values was not specified.
Further notes
You stop the recording early with the
wlan signal-recorder <wlan 0/X> stop
command.
You display the status of the signal recorder and the recording with the
show wlan signal-
recorder <wlan 0/X>
command.