RUGGEDCOM WIN5137
Installation Guide
Chapter 2
Installing the Device
Installing the Device in Hazardous Locations
19
Section 2.6
Installing the Device in Hazardous Locations
An approved surge suppression unit is required when the base station is installed in a hazardous location.
The WIN5137 is certified for installation in Class I, Division II Groups A, B, C and D hazardous locations when
installed using the Class I, Division II kit (P/N MKIT0090). The Class I, Division II kit contains the following items:
• Lambda power supply unit (model DPP50-48)
• L-COM passive PoE injector (model BT-CAT5-P1)
• DC power cable
• AC open-ended power cable (WIN5137-AC Only)
WARNING!
EXPLOSION HAZARD
• Substitution of components may impair suitability for Class I, Division II
• Do not disconnect equipment unless power has been switched off or the area is known to be non-
hazardous
• Use only Lambda DPP50-48 Power Supply in conjunction with the unit
RISQUE D’EXPLOSION
• La substitution decomposants peut rendre ce matériel inacceptable pour les emplacements de
Classe I, Division II
• Avant de déconnecter l’equipment, couper le courant ou s’assurer que l’emplacement est désigné
non dangereux
• Utilisez l’unité uniquement avec une batterie de la marque Lamba DPP50-48
To install the base station in a hazardous location, do the following:
1. Connect the DC power cable between the Lambda Power Supply Unit (PSU) and the L-COM passive PoE
injector.
4
1
6
2
2
3
5
Figure 18: Connecting the CPE in a Hazardous Location
1.
Ethernet Switch
2.
CAT-5e Cable
3.
L-COM Passive PoE Injector
4.
RUGGEDCOM WIN5137
5.
DC Power Cable
6.
Lambda PSU