Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols
 • ,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damage resulting from 
non-observance of the instructions and non-com-
pliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

D

GB

F

NL

I

E

1

32-00191-01

QUICK START GUIDE

Industrial Cellular Router 

OnCell 50A-LTE-EU

Safety

Contents

Safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage  . . . . . . . . . . . . . . . . . . . . . . 2
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Standards and Certifications . . . . . . . . . . . . . . . . 8
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

32-00191-01

Summary of Contents for OnCell 3150A-LTE-EU

Page 1: ...ctions and non com pliant use Safety instructions Information that is relevant for safety is indicated in the instructions as follows DANGER Indicates potentially fatal situations WARNING Indicates possible danger to life and limb CAUTION Indicates possible material damage All interventions may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qua...

Page 2: ...tal relay and 2 digital inputs 3 Grounding screw M5 4 2x2 MIMO antenna ports for LTE female SMA 5 RS 232 serial console RJ45 6 10 100 Base T X Ethernet port RJ45 7 LED display 8 DIN rail mounting kit 9 Reset button 10 Dual SIM SIM1 11 Dual SIM SIM2 Configuration Before configurating the OnCell G3150A LTE make sure that all items in the package checklist are in the box In addition you will need acc...

Page 3: ...l atten tion and take special precautions before handling this equipment Only authorized well trained professionals should be allowed to access the restricted access loca tion Access should be controlled by the authority responsible for the location with lock and key or a security identity system External metal parts are hot Pay special at tention or use special protection before handling this equ...

Page 4: ...han 3 5 mm in diameter 6 mm 3 5 mm Test the screw head and shank size by insert ing the screws into one of the keyhole shaped apertures of the wall mounting plates before attaching the plates to the wall 4 Once the screws are fixed into the wall insert the four screw heads through the large opening of the keyhole shaped apertures 5 Then slide the OnCell G3150A LTE downwards 6 Tighten the four scre...

Page 5: ...n the ground connection from the ground screw to the grounding surface prior to connecting devices The minimum cross sectional area of the ground ing conductor should be equal to that of the input cable ATTENTION This product is intended to be mounted on a well grounded mounting surface such as a metal panel The potential difference between the two ground potentials must be zero If the potential d...

Page 6: ...er an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa OnCell G3150A LTE s console port to your PC s COM port You may then use a console terminal program to access the OnCell G3150A LTE for configuring the console configuration Console Pinouts for 10 Pin or 8 Pin RJ45 10 Pin Description 8 Pin 1 12345678 2 DSR 1 3 RTS 2 4 GND 3 5 TxD 4 6 RxD 5 7 6 8 CTS 7 9 DTR 8 10 The pin numbers for both 8 ...

Page 7: ...SIM 1FF GNSS 1 SMA female GPS 1575 42 MHz GLONASS 1602 MHz Ethernet 1 10 100 Mbps auto negotiation speed F H duplex mode and auto MDI MDI X connection RJ45 type Serial Console Port 1 RS 232 RJ45 type Serial Port 1 RS 232 RS 485 4W RS 485 2W RS 422 DB9 male Serial Communication Parameters Data Bits 5 6 7 8 Stop Bits 1 1 5 2 when parity None Parity None Even Odd Space Mark Baudrate 75 bps to 921 6 k...

Page 8: ...0 C non condensing Power Requirements Input Voltage 12 to 48 VDC redundant dual DC power inputs Connector 4 pin removable terminal block Power Consumption 9 6 W 12 V 0 78 A to 48 V 0 2 A Reverse Polarity Protection Present Reliability MTBF 528 596 hours Standards and Certifications Safety OnCell G3150A LTE US UL 60950 1 EMI OnCell G3150A LTE US FCC Part 15 Subpart B EMS OnCell G3150A LTE EU EN 610...

Reviews: