RUGGEDCOM WIN5137
Installation Guide
Chapter 2
Installing the Device
Assembling the PoE Cable
15
Figure 11: Untwisting the Wire Pairs
6. Arrange the wires according to the following pin-out description:
1
2
Figure 12: CAT-5e PoE Cable Pin-Out
1.
Pin 1
2.
Pin 8
Pin
Number
Color
Description
1
White/Orange
ETH Data
TP0+
2
Orange
ETH Data
TP0-
3
White/Green
ETH Data
TP1+
4
Blue
48 V
TP2+
5
White/Blue
48 V
TP2-
6
Green
ETH Data
TP1-
7
White/Brown
RTN (-)
TP3+
8
Brown
RTN (-)
TP3-
7. Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.
1
2
2
1
1
3
4
Figure 13:
1.
Loading Bar
2.
Wires
3.
Pin 1
4.
Pin 8
8. Trim the wires until they are flush with the face of the loading bar.
9. Insert the wires and loading bar into the plug body. Make sure:
• the cable is pushed to the front of the plug body
• the spine of the strain relief on the plug body covers the drain wire
10. Bend the strain relief until it is flat against the jacket and foil.
11. Crimp the plug and strain relief using a standard crimping tool.