background image

 

® U.S. Registered Trademark 

  

EN1B-0241GE51 R0106C 

Copyright © 2006 Honeywell Inc. • All rights reserved 

T7270B1009 

WIRELESS WALL MODULE 

 

HONEYWELL EXCEL 5000 OPEN SYSTEM

 

INSTALLATION AND OPERATING INSTRUCTIONS 

Summary of Contents for T7270B1009

Page 1: ... U S Registered Trademark EN1B 0241GE51 R0106C Copyright 2006 Honeywell Inc All rights reserved T7270B1009 WIRELESS WALL MODULE HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS ...

Page 2: ...llowing six basic functions LIGHT SUNBLINDS OCCUPANCY FAN SETPOINT OFFSET and TEMPERATURE DISPLAY TRANSMIT function NOTE The LIGHT function is the default function see also section Default Function on page 5 and Fig 2 Controls The wall module features three control buttons and a large setpoint wheel They are used in the operating mode to select individual functions and to adjust their respective s...

Page 3: ...s LI are displayed in the LCD and the function indication bar appears underneath the light symbol imprinted on the housing NOTE See also section Default Function on page 5 Controlling a Single Light Group P6 1 If the wall module has been configured to control only a single group of lights see section P6 Light Groups on page 6 the LIGHT function settings are performed as described in the following ...

Page 4: ... the DOWN Button Briefly pressing the DOWN button will completely lower the sunblinds in the LCD the sunblinds symbol moves downwards Briefly pressing either the UP or the DOWN button while the sunblinds are descending will stop the sunblinds and the LCD will revert to the default display Pressing the DOWN button for more than 2 sec will lower the sunblinds only as long as it remains pressed in th...

Page 5: ...through the other function symbols Power Up Teach Commands After power up an LCD test will be carried out i e all LCD segments will be activated for approx 1 sec Fig 3 LCD test after power up After that two teach commands will be triggered Please refer to W7070A Receiver System Engineering Product Literature No EN0B 0286GE51 on how to perform a teach in A special LCD sequence t 1 then t 2 will be ...

Page 6: ...tion becomes the default function P7 Room Temperature Correction Value With this parameter the user can correct the room tem perature value displayed in the LCD and transmitted to the W7070A receiver A value of 50 means no change i e the temperatures measured by the wall module are displayed transmitted without correction This is the default configuration Values of 49 48 47 etc mean that the tempe...

Page 7: ...ecified on the installation drawings to allow exposure to the average zone temperature Do not mount the wall module on an outside wall on a wall containing water pipes or near air ducts Avoid locations that are exposed to discharge air from registers or radiation from lights appliances or the sun Fig 4 Mounting Removing the Housing Cover The wall module comes with a sub base that mounts separately...

Page 8: ...te du Bois 37 Switzerland by its Authorized Representative Automation and Control Solutions Honeywell GmbH Böblinger Straße 17 D 71101 Schönaich Phone 49 7031 63701 Fax 49 7031 637493 http europe hbc honeywell com Subject to change without notice Printed in Germany EN1B 0241GE51 R0106C DIMENSIONS F Honeywell 104 85 99 97 2 30 68 100 86 Fig 6 T7270B1009 dimensions in mm ...

Reviews: