EMC and Environmental Type Tests
39
Test
Description
Test Levels
Severity
Levels
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC 61000-4-29
Voltage Dips & Interrupts
AC Power ports
30% for 1 period, 60% for 50 periods
IEC 61000-4-11
Voltage Dips & Interrupts
AC Power ports
100% for 5 periods,
100% for 50 periods
Signal ports
2.5 kV common, 1 kV
differential mode @1 MHz
3
DC Power ports
2.5 kV common, 1 kV
differential mode @1MHz
3
IEC 61000-4-12
Damped Oscillatory
AC Power ports
2.5 kV common, 1 kV
differential mode @1MHz
3
Signal ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power ports
30 V Continuous, 300 V for 1 s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power ports
10%
3
Signal ports
2 kV (Fail-Safe Relay output)
DC Power ports
2 kV
Dielectric Strength
AC Power ports
2 kV
Signal ports
5 kV (Fail-Safe Relay output)
DC Power ports
5 kV
IEC 60255-5
HV Impulse
AC Power ports
5 kV
a
Siemens-specified severity levels
IEEE 1613 EMC Type Tests
NOTE
The RUGGEDCOM MX5000 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
Description
Test Levels
Enclosure Contact
+/-2 kV, +/-4 kV, +/- 8 kV
ESD
Enclosure Air
+/-4 kV, +/-8 kV, +/-15 kV
Radiated RFI
Enclosure ports
35 V/m
Signal ports
+/- 4 kV @ 2.5 kHz
DC Power ports
+/- 4 kV
AC Power ports
+/- 4 kV
Fast Transient
Earth ground ports
+/- 4 kV
Signal ports
2.5 kV common mode @1 MHz
Oscillatory
DC Power ports
2.5 kV common, 1 kV differential mode @ 1 MHz