ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 54 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
5.5
Without entry/exit monitoring
EAKO = ’4’
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉ
ÉÉ
ÉÉ
Prox. switch I
Direction of
movement of
MDS
MDS
Prox. switch II
ÉÉ
ÉÉ
ÉÉ
Computer
or PC
ASM 421
SLG
Dig. inputs
ANW
In this mode of operation, the user assumes control of the MDS. Proximity switch I signals to the computer
that an MDS has entered. The MDS does not have to be within the transmission window of the SLG at this
time. Command processing begins as soon as the MDS enters the transmission window. The user can
check this by interrogating the ANW bit or the Z message.
Proximity switch II at the MDS exit point is not absolutely necessary.