ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 43 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
Acknowledgement:
’X’
CC Status ADB
DBN DBL
00
xx
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
05
00
11/14
15
Error code
ANW
Proximity status (1 byte ASCII)
’0’
= no MDS in the SLG field
’1’
= MDS in SLG field
The error code is normally 0000. These 4 characters only contain
information if the status byte (byte 5) shows an error.
Important:
The ASM 421 must receive a RESET telegram from the user whenever power is restored. Any other
type of telegram will be rejected with an error.
A RESET command sets the parameters for the file handler on the ASM 421 , which starts to function (the
single blinking of the red LED ceases and the yellow LED must come on, if the connection to the SLG is
OK). The RESET command is required when a command or a sequence of telegram blocks is to be
aborted.
If a command is terminated by the file handler with an error, no RESET command is necessary.
Please note:
A RESET command declares the current MDS directory on the ASM to be invalid. For the next MDS to be
processed, the directory must in each case first be read from the MDS. To avoid the time delay inherent in
reading the directory, the MDS directory can be loaded by the user into the ASM with the LOAD command
immediately after the RESET command (see section 3.4.16).
Definition of t
ABTAST
:
t
ABTAST
is parameterized as a hex value.
Bit:
7
6
5
4
3
2
1
0
Time factor:
Time value: 00-3F
00 =
0.01 sec
01 =
0.1
sec
10 =
1
sec
11 =
10
sec
For detailed explanation of t
ABTAST
, see the configuration manual for SLG 44/MDS 507/MDS 407E.