ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 26 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
Acknowledgement:
’Q’
CC Status ADB DBN DBL
00 xx 0000
ADB
0
1
2/3
4
5
6/7
8/9
10
00
0001 00
Handling of Errors:
If the file handler detects a syntax error in the structure of the transmitted file entry, the QUEUE-WRITE
command is aborted with an appropriate error message. In addition, the QUEUE-WRITE command is
aborted with the option = 0001 hex if the file handler determines that the file to be set up already exists.
Error Identification for Parameter Error in File Entry:
K x
x
x
“xxx” stands for the number of the file entry in which an error was found. Counting of the file entries begins
with 1.
Example: Error message “K002”
→
Error in the second file entry.