3.4.14
NEXT
The NEXT command terminates the processing of an MDS. The command after the NEXT command will
only be processed if a new MDS enters the transmission window of the SLG.
Telegram to the file handler:
’N’
CC CI
ADB
DBN DBL
xx
00
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
00
’I’
Acknowledgement:
’N’
CC Status ADB
DBN DBL
00
xx
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
00
00
It is essential to program the NEXT command for the following types of entry / exit checking (EAKO):
– MDS recognition by field scanning:
– MDS control via 1 DI:
EAKO = 2 and field scanning (see section 5.3)
– MDS control via 2 DI:
The NEXT command does not need to be programmed for the operating modes “timeout” and “without
entry / exit checking”. Should it nevertheless be programmed, it will be processed in all its aspects by the
file handler.
Further information about this command can be found in section 5.