5.3
MDS control using field scanning and 1 DI
EAKO = ’2’
Schematic layout:
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
Direction of
movement of
MDS
MDS
Prox. switch
on DI 0
Computer
or PC
ASM 421
SLG
ÉÉ
ÉÉ
The entry of an MDS is detected by a proximity switch connected to DI 0. The switch should be positioned
so that the MDS is guaranteed to be in the transmission window if the switch is activated. If this is not the
case, or if the MDS is defective, an error will be reported. After processing the MDS, it is imperative that
the user send a NEXT command to the ASM. The file handler assumes complete and continuous control