Appendix G: Menu Structure Quick Reference
Siemens Power Transmission & Distribution, Inc.
65
G
Menu Structure Quick Reference
G.1
Navigating the Menu and Fast-Path Keys
Figure G.1
Navigating the Menu and Fast-Path Keys
(By-Pass
4.0 / 6.0A
Power
Circuit Protection Fuses
120 VAC
Ground
4.0 / 6.0A
External
Position)
.4A
Sensing
Ground
Voltage
Raise
Alert
High Band
Lower
Lower
Raise
Delay
Level
width
(By-Pass
Position)
Voltage Reduction Control
Off
External
Normal
Power
TM
Neutralite
VRC
Neutral Status
Test
(Enable)
Remote
Manual
Tap Control
Auto
Local-
Select
VRC
Remote Auto Inhibit
Reverse Power Flow
Change
Voltage
Reset
Band-
Regulation Setting
Data Port
Cancel
Min
Time
In Band
Low Band
Save
Max
tance
tance
Reset
Voltage Calibration / Test
(By-Pass
Position)
Off
P2
U2
Lower
Drag Hands Reset
Voltage Limit Control
Upper
VLC
Select
Op
Count
Line Drop Compensation
Quick
+
Resis-
Alert
Reac-
Status
Menu
Accu / Stat MJ - X
R
L
Press to scroll (left) across menu
headings. (From Meter to
Passwords to Diagnostics, etc.)
Press Change, and then press
here to move cursor to left.
Press to scroll (up) through data
items within column. Press
Change, and then press here to
change setting choices.
Press once to reach menu
heading. Press twice to reach
"home" (<METER>).
Press to scroll (right) across menu
headings. (From Meter to
Fw Demand to Rev Remand, etc.)
Press Change, and then press
here to move cursor to right.
Press to scroll (down) through
data items within column. Press
Change, and then press here to
change setting choices.
Press to view First Active Alert.
Repeat to scroll through Active
Alerts.
Press to view Total Operations
Count. Repeat to scroll through
<COUNTERS> items.
Press to view Forward Line Drop
Compensation (LDC) Reactance
setpoint. (Press again for reverse.)
Press Change, then press here to
change sign after viewing Resis-
tance or Reactance Compensation
Press to view Voltage Limit Control
(VLC) Enable status. Repeat to
scroll through VLC settings.
Press here to reset the electro-
mechanical drag hands on the
regulator Position Indicator to the
present tap changer position.
This also resets the electronically
stored max/min tap position
values (viewable from the display).
Press here to view the U2 voltage
at the PDS. Press again to view
the P2 voltage at the PDS. Use
this key for calibrating the panel.
See Section 8.4 for details.
Press to view Forward Line Drop
Compensation (LDC) Resistance
setpoint. (Press again for reverse.)
Press to Cancel changes
without saving. Press to reset
displayed Max/Min item to
present value. Press to
Acknowledge displayed Alert.
Press to change settings.
(For configuration items only.)
Press to save changed settings.
Press once to view Maximum.
Press again to view Minimum
Press 3rd time to exit Max/Min
view.
Press to view Forward Voltage
setpoint.
(Press again for Reverse.)
Press to view Forward
Bandwidth setpoint.
(Press again for Reverse.)
Press to view Forward Time
Delay setpoint.
(Press again for Reverse.)
Press to view Voltage Reduction
Control (VRC) status. Repeat
to scroll through VRC settings.
Press here to test the
Neutralite Indicator.
(This is a lamp test.)