![Siemens Milltronics BW100 Instruction Manual Download Page 8](http://html.mh-extra.com/html/siemens/milltronics-bw100/milltronics-bw100_instruction-manual_374197008.webp)
Page 4
Milltronics BW100 - INSTRUCTION MANUAL
7ML19985DJ01
mmmm
m
Specificat
ions
Inputs
• load cell:
0 - 45 mV dc per load cell
• speed sensor:
pulse train: 0-5 V low, 5-15 V high, 1 to 2000 Hz,
or
open collector switch
or
relay dry contact
• auto zero:
dry contact from external device
Outputs
• analog:
- optically isolated 0/4 - 20 mA
- 750
Ω
max loading
• resolution:
- 0.1% of 20 mA
• load cell:
- 10 Vdc compensated for strain gauge type, 2 cells max
• speed sensor:
- 12 Vdc, 50 mA max excitation
• remote totalizer 1:
- contact closure 32 - 288 ms duration
- open collector switch rated 30 Vdc, 100 mA max
• remote totalizer 2:
- contact closure 32 - 288 ms duration
- open collector switch rated 240 Vac/dc, 100 mA max
• relay output:
programmable function 1 form C SPDT relay contact rated
5 A at 250 Vac, non-inductive
Communications
• Dolphin compatible
• proprietary bipolar current loop
Cable/Separation:
• one load cell/LVDT:
non-sensing:
Belden 8404, 4 wire shielded, 20 AWG or equivalent,
150 m (500 ft.) max.
sensing:
Belden 9260, 6 wire shielded, 20 AWG or equivalent,
300 m (1000 ft.) max.
• two load cells:
non-sensing:
Belden 9260, 6 wire shielded, 20 AWG or equivalent,
150 m (500 ft.) max.
sensing:
Belden 8418, 8 wire shielded, 20 AWG or equivalent,
300 m (1000 ft.) max.
• speed sensor
Belden 8770, 3 wire shielded, 18 AWG or equivalent,
300 m (1000 ft.) max.
• auto zero:
Belden 8760, 1 pair, twisted/shielded, 18 AWG, 300 m
(1000 ft.) max.
• remote total:
Belden 8760, 1 pair, twisted/shielded, 18 AWG, 300 m
(1000 ft.) max.