English
2. INSTALLATION – MICROMASTER Vector
G85139-H1751-U529-D1
© Siemens plc 1999
4/8/99
24
2.2.6 Block Diagram - MICROMASTER Vector
M
PE
U, V, W
17
CPU
AD
SI
RS485
1 - 3 AC 208 - 230 V
3 AC 380 - 500 V
2
3
L/L1, N/L2
or
L/L1, N/L2, L3
4
B-
15
26
25
24
23
22
21
20
13
14
5
PE
B+/DC+
1
+10V
0V
OR
PE
V:
16
0 - 10 V
2 - 10 V
0 - 20 mA
4 - 20 mA
I
:
AIN1+
AIN1-
PE
³
4.7 k
W
AOUT+
AIN2/PID -
RL2
P+
N-
RS485
AD
AIN2/PID+
~
6
7
8
9
12
24 V
10
11
OR
+15V
–
+
DIN1
DIN2
DIN4
DIN3
DIN6
DIN5
P
Jog
DA
AOUT-
5V+
Motor
PTC
3
~
R
DIP Switches
5
2
4
3
1
18
19
RL1
Figure 2.2.6 Block Diagram - MICROMASTER Vector