2 Installation
Issue 10/06
MICROMASTER 430 Operating Instructions
22
6SE6400-5AE00-0BP0
2.2
Ambient operating conditions
Temperature
Frame Sizes G to F:
Frame Sizes FX and GX:
0
20
30
10
40
[°C]
Ambient temperature
50 55
95
100
[%]
Permissible output current
90
85
45
0
20
30
10
40
[°C]
Ambient temperature
-10
50
60
constant torque
variable torque
75
50
25
100
[%]
Permissible output current
Figure 2-2
Ambient operating temperature
Humidity Range
Relative air humidity
≤
95 % Non-condensing
Altitude
If the inverter is to be installed at an altitude > 1000 m or > 2000 m above sea
level, derating will be required:
Permissible output current
Installation altitude in m above sea level
Permissible input voltage
80
100
0
1000
2000
3000
4000
%
Installation altitude in m above sea level
77
85
100
0
1000
2000
3000
4000
%
80
Frame Sizes
FX and GX
Frame Sizes
A to F
Figure 2-3
Installation altitude
Shock and Vibration
Do not drop the inverter or expose to sudden shock. Do not install the inverter in an
area where it is likely to be exposed to constant vibration.
Mechanical strength to EN 60721-3-3
¾
Deflection:
0.075 mm (10 ... 58 Hz)
¾
Acceleration:
9.8 m/s
2
(> 58 ... 200 Hz)
http://nicontrols.com