BA 9137 en 12/2015
7.1.2
Removal of preservative agent from interior
Note
The required measures prior to start-up are described in the following, as dependent on the basic
preservation applied (see Technical data) on the gear unit.
Detailed descriptions of the procedure as well as regarding the particularities, which must be taken into
account, can be found in the following items 7.1.3 to 7.1.5 and in the separately provided operating
instructions BA 7300.
Table 10:
Measures before the start-up of gear units, which have
not been taken into operation
before,
are as follows depending on the gear unit basic preservation / prolongation of
preservation.
Kind of basic
preservation
Kind of preservation
prolongation
Measures before
Start-up
Castrol Alpha SP 220 S
– None
– Fill with operating oil.
Castrol Alpha SP 220 S
– Castrol Corrosion Inhibitor N 213
<= 5 % operating oil quantity
– Fill with operating oil.
Castrol Alpha SP 220 S
– Castrol Corrosion Inhibitor N 213
> 5 % operating oil quantity
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
Castrol Alpha SP 220 S
– Completely filled with operating
oil (mineral oil or oil on
PAO-basis)
– Drain preservative oil until operating oil
level is reached.
Castrol Alpha SP 220 S
– Completely filled with the
approved mineral oil (see
specification in BA 7300)
– Drain preservative oil and fill with new
operating oil.
Castrol Alpha SP 220 S
– Castrol Alpha SP 220
– Fill with operating oil.
Castrol Alpha SP 220 S
– Castrol Tribol 1390
– Flush with operating oil and fill with new
operating oil.
Castrol Tribol 1390
– None
– Flush with operating oil and fill with new
operating oil.
Castrol Tribol 1390
– Castrol Corrosion Inhibitor N 213
<= 5% operating oil
– Flush with operating oil and fill with new
operating oil.
Castrol Tribol 1390
– Castrol Corrosion Inhibitor N 213
> 5 % operating oil
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
Castrol Tribol 1390
– Completely filled with operating
oil (mineral oil or oil on
PAO-basis)
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
Castrol Tribol 1390
– Completely filled with the
approved mineral oil (see
specification in BA 7300)
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
Castrol Tribol 1390
– Castrol Alpha SP 220
– Flush with operating oil and fill with new
operating oil.
Castrol Tribol 1390
– Castrol Tribol 1390
– Flush with operating oil and fill with new
operating oil.