BA 9137 en 12/2015
Table 6:
Maximum durability period of the interior preservation of the gear unit through operating the
oil-supply system.
Setup in
climatic zone A
and at
least 50 km distance from larger
bodies of salt
water
Setup in
climatic zone B
and/or
less than 50 km distance from
larger bodies of salt water
Packaging for
Storage
Storage place of
packaged unit
Maximum durability period of the preservation renewal through
operation of the oil-supply system (in months)
No
packaging
exposed outdoors
5
3
covered with loose
tarpaulin
8
5
under roof
1)
20
14
in closed,
dry room
covered at least
with
loose tarpaulin
exposed outdoors
8
5
under roof
1)
24
17
in closed,
dry room
seaworthy
packaging
2)
exposed outdoors
20
20
covered with loose
tarpaulin
under roof
1)
24
24
in closed,
dry room
1) under roof:
no direct exposure to sunlight and no direct contact with water
(rain or draining water)
2) Seaworthy packaging:
use of wooden box lined with bitumen paper. The content is sealed in foil and protected against moisture
by addition of drying agents for the prescribed storage period.
Note
Before restarting the gear unit, the measures according to section 7.1 and 7.2 have to be carried out.