Installing and connecting the device
3.3 Mounting the PRO device
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
50
Operating Instructions, 07/2016, A5E31298376-AF
2. Grease the flange mount with grease
suitable for NBR seals and insert the
flange mount into the corresponding
opening of the PRO device.
3. Attach the flange mount with the two
supplied M8 grub screws, torque 8 Nm.
If you attach the PRO device to a round
tube prepared for Siemens devices, the
following torques apply:
•
Round tube made of steel: 8 Nm
•
Round tube made of aluminum: 5 Nm
4. If an adapter plate for the Siemens flange
mount is included with your support arm,
attach the adapter plate to the support arm
with 4 M6x12 screws. Pay attention to the
torque that is specified for the support arm.
5. Insert all connection cables through the
opening of the flange mount into the
terminal compartment of the PRO device.
Make sure that the connection cables are
not damaged.
6. Attach the device with 4 M4x12 screws to the support arm from the below. The screws are not included in
the product package of the PRO device. Pay attention to the torque that is specified for the support arm.
Make sure that the connection cables are not crushed.
7. Connect all cables according to the description in the section below.
8. Fasten the terminal compartment cover to the device with the 2 screws, torque 1.5 Nm. Check that the
seal is sitting correctly.
9. Attach the lower cover supplied with the PRO device with 4 M4x12 screws, torque 1.5 Nm.