Technical information
7.5 Technical specifications
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF
101
7.5.2
Ambient conditions
7.5.2.1
Transport and storage conditions
Mechanical and climatic conditions for transportation and storage
The requirements regarding transport and storage conditions for the device are more
stringent than those laid down in IEC 60721-3-3. The following requirements apply to the
transport and storage of the device in its original packaging.
The climatic conditions conform to:
●
Class 3M3 (mechanical requirements)
●
Class 3K3 (climatic requirements)
Type of condition
Permitted range
Drop test (in transport package)
≤ 1
m
Temperature
From –20 to +60° C
Atmospheric pressure
From 1080 to 660 hPa,
Corresponds to an elevation of –1 000 to 3 500 m
Relative humidity
From 10 to 90%, without condensation
Sinusoidal vibration in accordance with
IEC 60068-2-6
5 to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
Shock in accordance with IEC 60068-2-27
25 g, 6 ms, 1 000 shocks
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.