Installing and connecting the device
3.4 Connecting the device
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF
61
3.4.5.2
Connection versions
"Commissioning" mode
When you commission an Ethernet Monitor with the "Ethernet Monitor" software or want to
change the network parameters of an Ethernet Monitor, connect the Ethernet Monitor and
IPC in the "Commissioning" mode as follows:
1. Connect the Ethernet Monitor and IPC with a USB cable.
Maximum cable length: 5 m
USB Type B
2. Connect the Ethernet Monitor and IPC with a DisplayPort cable.
Maximum cable length: 5 m
DisplayPort
3. Connect the Ethernet Monitor and IPC with an Ethernet cable.
Ethernet
"Ethernet" mode
After commissioning, connect the Ethernet to the IPC via LAN. Cable
lengths or distances according to conventional LAN technology.
3.4.6
Connecting a USB device
Below are examples of devices you can connect to the USB interfaces of the device:
●
External mouse
●
External keyboard
●
USB memory stick
Note when connecting
Note
Use of USB devices
•
The cable length of USB peripherals cannot exceed 3 m.
•
Wait at least ten seconds between removal and reconnection of USB devices.
•
When using standard USB peripherals, bear in mind that their EMC immunity level is
frequently designed for office applications only. These devices may be used for
commissioning and servicing. However, only industry-standard devices are allowed for
industrial operation.
•
Peripherals are developed and marketed by individual vendors. The respective supplier
offers support for the I/O devices. Moreover, the terms of liability of the individual vendors
or suppliers apply here.