The table below shows the settings available for KS with optiPoint using U
P0/E
MODULES
:
Table 2-7
optiPoint and KS telephones for HiPath1150/1190/1190R.
Limitations:
If an 8-port U
P0/E
module is installed, the system will not free up another U
P0/E
module in the
system. Both the HiPath 1150 and the HiPath 1190 allow a maximum of 8 U
P0/E
ports, resulting
in 16 optiPoint telephones ( slave) + 8 KS telephones, for a total limit of 24 system
telephones. Therefore, only combinations of UP0/E modules are possible for a maximum of 8
ports.
2.5.3
Notes on HiPath 1150
If there are only 2 PCM highways in the HiPath 1150 and one module TME1 is used, we would
have 30 timeslots reserved and a further 2 timeslots reserved for the analog trunks, which
would mean fewer than 32 timeslots free for all the other extensions of the system. To avoid this
limitation, the solution was to use an additional highway based on the DSP control for slots 3
and 4.
Figure 2-5
Distribution of the highways in the HiPath 1150
Master/Slave/KS
None
U
P0/E
(2 Ports)
U
P0/E
(4 Ports)
U
P0/E
(8 Ports)
None
0/0/8
2/2/8
4/4/8
8/8/8
U
P0/E
(2 Ports)
2/2/8
4/4/8
6/6/8
2/2/8
U
P0/E
(4 Ports)
4/4/8
6/6/8
8/8/8
4/4/8
U
P0/E
(8 Ports)
8/8/8
8/8/8
8/8/8
8/8/8
SLOT 2
SLOT 1
SLOT 4
SLOT 3
Highway A
Highway B
Highway C
Summary of Contents for HiPath 1100
Page 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Page 14: ...Figures 14 Service Manual ...
Page 124: ...Modules 3 124 Service Manual Interconnect cables ...
Page 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Page 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Page 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Page 384: ...Abbreviations 9 384 Service Manual ...
Page 388: ...388 Service Manual ...