Service Manual
4-147
Installation
Installing modules
4.7.3.3
On the HiPath 1190/1190R
Installation Procedures
Step
Procedure
1.
Turn off the power supply.
2.
Remove the system’s front cover.
3.
Remove the system’s back cover.
4.
Move the module’s latch as shown in figure 4-12.
5.
Insert the module into one of the slots shown in Table 4-2.
6.
Move the module’s latch back to secure module.
7.
Connect the Main Distribution Frame cables as follows: For modules allocated to the
system’s bottom slots (slots 1 to 10) use the bottom opening (see figure 4-10). For
modules allocated to the system’s top slots (slots 11 to 20) route the cables through
the top anchors (See figure 4-11).
8.
Connect to the appropriate module Connectors (see “Expansion modules (EB)” on
page 3-58).
9.
Attach cables to anchors using plastic brackets.
10.
“Performing a visual inspection” on page 4-189.
11.
Reassemble the entire set.
12.
Turn on the power supply.
13.
Configure the required data (see “Operation” on page 7-278).
14.
*
*
This is necessary only if you have changed the type of the modules installed in your system.
Using Manager application go to: Advanced tab, > PBX Information tab, > Slot
Allocation tab;
Select the Clear All Slots checkbox;
Update the HiPath System;
Reset the HiPath System.
Summary of Contents for HiPath 1100
Page 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Page 14: ...Figures 14 Service Manual ...
Page 124: ...Modules 3 124 Service Manual Interconnect cables ...
Page 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Page 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Page 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Page 384: ...Abbreviations 9 384 Service Manual ...
Page 388: ...388 Service Manual ...