background image

*LJDVHW

0

' D W D

The cordless

 USB interface 

for connecting PCs to Gigaset 3070/75isdn

Operating Instructions

Please read the safety 
precautions outlined in these 
operating instructions before 
putting the unit into service!

+RZWRXVHWKLVPDQXDO

&RQWHQWV

,QGH[

Note

Summary of Contents for Gigaset M105 Data

Page 1: ...USB interface for connecting PCs to Gigaset 3070 75isdn Operating Instructions Please read the safety precautions outlined in these operating instructions before putting the unit into service RZ WR XVH WKLV PDQXDO RQWHQWV QGH Note ...

Page 2: ...rt 10 Click here to jump to this section 11 It may be useful to switch the operating mode from AT commands PC to one of the two other operating modes This setting con cerns the protocol on the serial interface especially the speed ad justment Setting the operating mode on page 12 12 Close the program with OK In the event of errors or for further information see Configuration program options on pag...

Page 3: ... A 1 Back Overview Side Port for the USB cable Front 1 Operating LED illuminated when power supply is active see LEDs on page 20 2 Data LED illuminated during data transfer operations ...

Page 4: ...n tab 11 Upper section connecting to the PC 11 Lower section DECT connection 11 Operating mode tab 12 Setting the operating mode 12 Special settings for Direct connection mode 13 Local adapter tab 15 Changing the name 15 Change adapter type 15 Registering a portable part 16 De registering a portable part 17 Automatic enabling 17 Remote adapter tab 18 Changing the name 19 Change PIN 19 LEDs 20 LED ...

Page 5: ...le connection via RS232 V 24 interface 26 Setting the direct connection to the correct baud rate 26 Sharing files 33 Examples of PC PC direct cable connection problems 34 What happens if 35 Support 36 Updates and news on the Internet 36 Notes on sending faxes directly from the PC 36 Problems with application programs 37 Technical data 39 Safety precautions 40 Index 41 ...

Page 6: ...05 Data features of a configuration program Meaning of local adapter and remote adapter These names are used for identifying the adapters and their role in data communication The Local adapter is the adapter that performs all con figurations also for the remote adapter This means that the Gigaset M105 Data setup routine does not have to be installed on the second PC in the case of a direct cable c...

Page 7: ...e through the registration option Only one Gigaset M105 Data Portable part can have an active connection to a Gigaset 3070 75isdn or a Gigaset M101 M105 Data Base Up to 6 portable parts or up to 6 bases can be registered multi link operation Contents of the package 1 Gigaset M105 Data 2 CD ROM with the installation program and operating instructions 3 Installation brochure 4 USB cable The Gigaset ...

Page 8: ...lation program Installing 1 Switch on the PC 2 Insert the CD in the CD ROM drive 3 Connect the USB port on the Gigaset M105 Data to the USB interface on your PCs by means of the USB cable provided The hardware assistant appears on the screen 4 If prompted to enter the source for the driver enter the CD directory for Windows 98 win98 Confirm all displays with OK or Next A new virtual COM port is no...

Page 9: ...ation mode press LED 3 Start the Gigaset M105 Data configuration program 4 Select the Local adapter tab 5 Click the Register button and enter the base station PIN 6 Find a registration location and click OK The registration procedure starts and the message If the required base is ready for registration the local adapter logs on Check that the base is ready for registra tion appears on the screen T...

Page 10: ...default 6 Click OK The registration operation starts and the message If the re quired base is ready for registration the local adapter logs on Check that the base is ready for registration appears on the screen The two devices are automatically synchronised There is now an entry in the Registered bases list 7 Give the local station a suitable name e g PC 8 Select the Remote adapter tab and give th...

Page 11: ... registration procedure starts and the message If the re quired base is ready for registration the local adapter logs on Check that the base is ready for registration appears on the screen The two devices are automatically synchronised An entry now appears in the Registered bases list 7 Assign a suitable name to the local adapter e g PC 8 Open the Remote adapter tab and assign a name to it e g Gig...

Page 12: ...it downstream of a Gigaset 3070 3075 Starting the configuration program Under Start select Programs followed by Gigaset M100 Data and fi nally Set Gigaset The configuration program offers a dialog box entitled Properties of Gi gaset M101 Data which contains the four tabs Connect Operating mode Local adapter und Remote adapter A number of special fields are also provided for special inputs ...

Page 13: ...ted to the PC As soon as the program finds an adapter or identifies the manually se lected interface it sends it the configuration command via the control lines This action switches the adapter to configuration status This is in dicated by the Status display in the dialog box Gigaset M105 Data can only be configured under these conditions Your Gigaset M105 Data will automatically switch the adapte...

Page 14: ...tches are performed auto matically if you select an operating mode for a Gigaset M105 Data unit Setting the operating mode Open the Operating mode tab and select one of the five modes The three connection types are used for different purposes Direct connection The permanent transmission parameters for the vir tual COM port are manually set at the computer without automatic baud rate or data format...

Page 15: ...u do not want to change any other parame ters In the event of malfunctions reduce the speed in the Bits per second field Set your communication software likewise to this value In the case of changes only permitted values are accepted in the individ ual fields even for manual inputs Dataflow control list You can set whether the data transmission is controlled by the hardware or software The usual s...

Page 16: ...connected to the V 24 terminal immediately stops outputting data in the direction of the terminal when a STOP signal is received and saves this data in its own memory This ensures that the PC only sends data that can be proc essed by the transmission route saved If local flow control is not acti vated the V 24 terminal s STOP signal is transferred to the PC During this time less than 10 ms the PC ...

Page 17: ... op erated at the peripheral device Other constellations however are possi ble in which both adapters are connected to a PC in order for example to create a cordless data connection between two PCs In this case the adapter type of one of Gigaset M105 Data units must be Base while the adapter type of the other must be a Base Or you can implement more than one remote adapter in order to control a se...

Page 18: ...t the Local adapter tab The following dialog box appears Up to six registered devices can be entered in the Registered adapter window Depending on the adapter type of the local adapter Registered adapter or Registered bases is displayed Select a registration location and click Register The following window appears when the local adapter is a Base factory setting is Portable part ...

Page 19: ...and click Unregister Automatic enabling The automatic enabling feature is not available with Gigaset3070 75isdn The data connection is automatically enabled as soon as usage stops The Permit automatic enabling feature eliminates the need to enable the data connection manually If the V 24 interface is not used for a set length of time no activity on the V 24 interface and control line DTR 0 then th...

Page 20: ...This tab is used for configuring the Remote adapter that is not connected to the PC Registration must be performed first so that the two Gigaset M105 Data units can communicate The Remote adapter tab is only available after registration on the Local adapter tab ...

Page 21: ...ts default 0000 to obtain authorisation to change the PIN and press the tab key Enter the new PIN and press the tab key Enter the new PIN in the Repeat new PIN field and click OK The PIN is changed if the new PINs entered are identical and if the correct old PIN is entered Otherwise a warning appears The PIN of the Gigaset3070 75isdn unit cannot be changed as descri bed ...

Page 22: ...s the status of the transmission route of the interface LED 1 flashes slowly The adapter is searching for the partner or has not been registered LED 1 flashes quickly The partner was found the data connection is not assigned to the transmission route LED 1 is constantly lit The partner was found the transmission route is on stand by LED 2 off No data transfer LED 2 flickers is lit Data transfer ac...

Page 23: ...between Base and Portable part is based on the DECT standard The Gigaset M105 Data complies fully with the relevant European directives Should you nevertheless experience sound or pic ture distortion with your satellite signal receiving equipment please get in touch with your dealer to have it tested for shielding faults Depending on the ambient conditions the maximum range for a radio connection ...

Page 24: ...erfaces are more than connectors They have an integrated da taflow control control lines data lines and an adjustable speed function Serial interface are used to transport data in various formats Modems are usually controlled with AT commands or proprietary proto cols that they receive via their serial interface On the basis of these com mands modems can recognise the data format and speed at whic...

Page 25: ...or AVM compatible PC this is the operating mode for the local adapter The Gigaset M105 Data unit determines the conditions on the serial interface in the same way as a modem In addition to the data the transmission parameters are also transmitted to the Re mote adapter which then transfers the data to the connected device 3 AT commands device or AVM compatible device in this operating mode the rem...

Page 26: ... up to a terminal z You must select the relevant connection partner in the configuration mask in order to switch between the various terminals This can be done in the Connection partner list in the Connection tab Î page 11 and via the Connect button in the Local adapter tab Î page 15 z If Gigaset 3070 3075isdn for example is selected as the connection partner then an incoming call at the modem for...

Page 27: ...aptop share a Gigaset 3070 3075isdn ba se modem z Only one data connection at a time can ever be set up from a portable part to the terminal z Simultaneous access from both portable parts to the Gigaset 3070 3075isdn modem is not possible z The data connection is automatically enabled if the data line is not ac cessed ...

Page 28: ...est remove the null modem cable and install the cable sup plied This accelerates fault detection and clearance If this is not possi ble the precise configuration is to be examined z The Gigaset M105 Data unit can be set to a fixed baud rate direct con nection 115200 bps with HW handshake Setting the direct connection to the correct baud rate 1 Open the terminal program First of all open a terminal...

Page 29: ... PC to another pro ceed with the second step 2 Set the direct cable connection parameters Exit the terminal program at one of the PCs Under the Win95 Start menu select Settings Control Panel and open the window Control Panel window Double click the System icon you should now see the System Properties window Select the Device Manager tab Find the Modem icon in the folder ...

Page 30: ...tings A 28 Back Double click the icon to expand the branch The setting Null Modem Ca ble at COMx should be available Select the appropriate COM port for your configuration and double click it to open another subfolder ...

Page 31: ... Connection Advanced Click OK to exit each window 3 Test the baud rate setting Open the direct cable connection program under Start Programs Accessories If this icon is missing you may have to reinstall the appropriate software from the Win 95 system CD To do this select Control Panel Add Remove Programs Windows Setup Communications Details Direct Cable Connection ...

Page 32: ...lect Change and activate Guest Then enter the interface e g Null Modem Cable at COM 1 To enable access by the other PC the host controlling party and guest accessing party as well as the file and print sharing option must be ac tivated ...

Page 33: ...int Sharing in the sub window Set the parameters here If a change was made new drivers are loaded and Windows must be restarted If file and print sharing was already activate the computer does not need to be restarted Otherwise restart your computer ...

Page 34: ...essing 1 s should now appear The message CLIENT should appear a number of times in the terminal program of the connected computer If this is the case repeat the steps already described at the other compu ter If the Client message does not appear please try the following z Close the Direct Cable Connection window z Open the Task Manager by pressing CTRL ALT DEL If you see a task called Rnaapp selec...

Page 35: ...ade to the File Manager Explorer here is the correct procedure Once file sharing has been activated and the PC restarted you can release files for processing by the other PC via the File Manager Explorer Start the Explorer Select the relevant folder and the click File1 Properties The following window containing the tabs General and Release appears ...

Page 36: ...cial ISDN TA drivers CAPI modem drivers or similar software are of ten the cause of the problem Once successfully put into service you can start up the direct cable con nection at both computers Do not forget that one PC must be set as the host and the other as the guest Access to files should also be enabled via the settings Network File and Print Sharing Finally the subfolders to be accessed by ...

Page 37: ...n transmission parameters in your com munication software If the malfunction persists after checking all the above points call the hot line at 0180 5 333 220 If you are in Austria and your unit z is connected to a single connection contact the Siemens hotline at 01 1707 5004 z is connected to a telephone system contact the relevant installation company e g Siemens Nebenstellenanlagen in Vienna NÖ ...

Page 38: ...ass 1 does not support signal runtime delays which are required for switching to radio mode Class 2 mode on the other hand is less sensitive Nevertheless interfer ence can still occur here due to a bad radio link If you have problems with this setting start the configuration program and check the transmission quality under Connection and improve the quality of the connection by moving the Gigaset ...

Page 39: ...Gigaset M105 Data unit to the factory defaults The preset PIN is 0000 Fault Cause Solution PC PC direct cable con nection under WIN98 can not be configured or is not working Baud rate not correctly set See PC PC direct cable connec tion via RS232 V 24 interface on page 26 Fax function is not working SW and modem simulate a Class1 fax Class 1 fax mode is not supported by Gigaset M105 Data for techn...

Page 40: ...plink 7 0 is not working Data transmission is switched during transmission AT Hayes commands are not used for this None Fault Cause Solution Fault Cause Solution Monitor fault when Gigaset M105 Data is active e g slight flickering or moiré effect DECT HF wanted signals is in fluencing the monitor Move Gigaset M105 Data along the longitudinal axis until the interference disappears Move Gigaset M105...

Page 41: ...ed power 10 mW average rating per channel Range up to 300 m outdoors up to 50 m indoors Power supply USB powered Power consumption Stand by mode approx 4 W Data transfer mode approx 5 W Permissible ambient conditions for operation 5 C to 45 C 20 to 75 relative humidity USB port Type B socket Standards complied with DECT in accordance with CTR 6 Electrical safety in accordance with EN 60950 ...

Page 42: ...ces Gigaset M105 Data can cause unpleasant humming in hearing aids Do not install Gigaset M105 Data in bathrooms or showers Do not operate Gigaset M105 Data in environments where there is risk of explosion Do not forget to include the operating instructions and CD when passing on Gigaset M105 Data to a third party We Siemens AG declare that the above mentioned product is manufactured according to ...

Page 43: ...DECT connection 11 Direct cable connection parameters 27 Direct connection 12 13 23 Download 22 E Enabling time 17 F Fax function does not work 37 Flow control 14 H Hardware RTS CTS 13 I Implementation options 24 Initial configuration 7 Installation 6 L Laplink 7 0 38 Laptop 24 LEDs 20 Local adapter 4 15 Local flow control 14 Loudspeaker hums slightly 38 M Memory 6 Modem 24 Monitor flickers slight...

Page 44: ... at Gigaset M101 Data 9 Registering at Gigaset M105 Data 8 Registration not possible 37 Remote adapter 4 18 de registering 17 18 registering 16 Request To Send 13 S Special features 22 Status LED 20 T Tab Connection 11 Local adapter 15 Operating mode 12 Remote adapter 18 Tips 24 U USB bus cable and M105 4 22 W What happens if 35 X Xmodem 38 ...

Reviews: