7
GB
Cleaning
■
Clean externally with a mild cleaning agent. Do not use
aggressive or abrasive detergents!
Maintenance/Customer Service
■
Repairs and other maintenance work may only be
carried out by one of our authorized customer service
representatives in order to avoid potential sources of
danger.
■
When you contact customer service, please quote the E
and FD numbers on your appliance (Fig. A).
■
The first inspection must be carried out no later than 2
years subsequent to initial startup of the appliance. This
involves inspection of the protection anode which may
need to be replaced, and the appliance may need to be
cleaned and descaled. The customer service will suggest
the next inspection date for a service.
■
The power supply and the water supply must be shut off
before all work on the appliance.
■
After service work is complete, proceed as during startup.
See IV. Startup
T e c h n i c a l d a t a
Rated capacity
[l]
30
50
80
100
Rated voltage
[V]
220–240 (~ 50 Hz)
Rated output DGxxx36E:
Rated output DGxxx36R:
Rated output DGxxx36P:
[W]
1500
2000
2000
Rated current DGxxx36E
Rated current DGxxx36R
Rated current DGxxx36P
[A]
6.5
8.7
8.7
Fuse protection
[A]
10
Protection type / class
IP24D
Rated over-pressure DGxxx36E:
Rated over-pressure DGxxx36R:
Rated over-pressure DGxxx36P:
[Mpa]
0.9
0.9
0.6
Cold and warm water connection
G 1/2"
Corrosion prevention
Magnesium protection anode
Warm water temperature range
[°C]
approx. 35–75
Frost protection
[°C]
approx. 15
Insulation thickness
[mm]
30
35
Stand-by power consumption at
65 °C
[kWh/d]
0.65
0.85
1.05
1.25
Mixed water quantities at 40 °C
(15 °C/65 °C)
[l]
54
90
144
180
Heating time (inlet 12 °C -> 60 °C)
DGxxx36E
DGxxx36R/DGxxx36P
[min]
68
51
114
85
182
137
228
171
Weight [filled]
[kg]
49
70
107
131
Dimensions (H x D)
[cm]
58 x 39
65 x 45
90 x 45
109 x 45