14
en
Congratulations on purchasing this Siemens
appliance. You have acquired a top-quality product,
which will give you a lot of enjoyment.
Please read this installation and operating in-
struction manual carefully, then act accordingly!
Store for future reference.
Installation instructions
Install the continuous-flow heater as described in
the illustrated section. Observe the instructions
in the text.
The illustrations can be found in the centre of the
instruction manual.
Unpacking
■
Inspect the new appliance for transport damage!
■
Please dispose of the packaging, and if appli-
cable, the old appliance in an environmentally-
friendly manner.
I.
Scope of delivery
1 Housing
2 Mounting (3 screws, 3 wall plugs)
3 Operation indicator
(only on DE06111M and DE08111M)
4 Installation bracket
5 Mounting bracket
6 Aerator
7 Documentation
Product description
The electronic continuous-flow heater is suitable for
both open (unpressurised) and closed (pressurised)
connections. It heats the water as it passes through
the appliance.
The continuous-flow heater switches on and heats
the water when the warm water tap is opened. It
switches off as soon as the tap is closed.
The appliance may not be operated with pre-heated
water, as otherwise the overtemperature protection
will trip.
This installation and operating instruction manual
describes various appliance types:
Over-sink appliances:
– DE06111M and DE08111M:
for fixed electrical connection
Undersink appliances:
– DE04101M and DE10104M: with plug connection
– DE05101M, DE06101M and DE08101M:
for fixed electrical connection
Only for permanently installed appliances:
The device is compliant to IEC 61000-3-12.
II.
Preparations for installation
■
Shut off the water supply before connecting
the appliance. The electrical connection must
be disconnected from the mains supply. Un-
screw the fuse or switch off the circuit breaker.
For all appliances
A clearance of about 60 mm on all sides of the
appliance is required for installation.
■
Observe the technical appliance data.
■
Break out the installation bracket from the rear
of the appliance (A).
Only for DE04101M and DE10104M
■
Break out one of the side knock-outs (B1) pro-
vided for an incoming electrical supply cable.
■
Feed the desired length of the incoming electri-
cal supply cable downwards through the knock-
out (B2).
■
Important: Connect the unit only to a mains
socket with protective contact that is installed
according to regulations. Do not use an exten-
sion cord. If necessary, equip the unit with a
longer cord.
Only for DE05101M, DE06101M,
DE06111M, DE08101M and DE08111M
(fixed electrical connection)
■
Press the upper and lower latches (C1), then
remove the housing cover (C2).