18
en
Operating instructions
Please read and observe the detailed safety
instructions at the start of these instructions!
■
Important: The appliance may never be exposed
to frost!
Risk of electric shock!
Switch off the mains voltage supply
immediately if a fault occurs (DE05101M,
DE06101M, DE06111M, DE08101M,
DE08111M) or disconnect the plug from
the mains supply (DE04101M, DE10104M).
■
Immediately shut off the cold water supply to
the appliance should it leak.
Operation
The electronic continuous-flow heaters of this series
operate automatically.
Switching on
■
Open the tap fully. The electronic continuous-
flow heater switches on. The water is heated as
it flows through the appliance.
The over-sink appliances DE06111M and
DE08111M feature an automatic operation indi-
cator. The operation indicator lights yellow at half
power and red at full power, dependent on the
water flow rate.
Switching off
■
Close the tap, and the appliance will switch off.
Regulating water temperature
■
Open the tap fully, and the appliance switches on.
■
Now increase the temperature of the water by
reducing the flow of water.
Info: In winter, the temperature of the water supply
may be lower, so that the temperature of the water
leaving the tap will not be reached. Please proceed
as described under “Water connection”.
0
10
20
30
40
50
7,2 kW
6,0 kW
4,5 kW
3,6 kW
1,2 1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 4,0 4,2
ΔT
[°C]
Q
[l/min]
The temperature of the water leaving the tap is dependent on the flow of water: