15
en
III.
Wall mounting
Undersink appliances
■
Attach mounting template D to the wall.
■
Mark the locations for the holes; drill the holes
and insert the wall plugs.
■
Attach the installation bracket to the wall using
the screws (D1).
Only for permanently installed appliances:
■
Pass the connection cable through the cable
grommet, suspend the appliance in the instal-
lation bracket and screw it onto the mounting
bracket (D2).
Only for appliances with mains plug:
■
Suspend the appliance in the installation bracket
and screw it onto the mounting bracket (D3).
Over-sink appliances
■
Attach mounting template E to the wall.
■
Mark the locations for the holes; drill the holes
and insert the wall plugs.
■
Attach the installation bracket to the wall (E1).
■
Pass the connection cable through the cable
grommet, suspend the appliance in the instal-
lation bracket and screw it onto the mounting
bracket (E2).
Only for DE05101M, DE06101M,
DE06111M, DE08101M and DE08111M
(fixed electrical connection)
■
The variants for feed through of cables using
flush mounting electrical connection should be
observed on the mounting template.
■
The cable grommet must completely enclose the
connection cable to guarantee optimum protec-
tion against dampness. The opening must be
sealed watertight if it is damaged.
■
Use the openings provided on the rear for
mounting.
IV.
Water connection
Left: pressurised (closed);
right: unpressurised (open)
■
The appliance is only approved for heating water
with a specific electric resistance of ≥ 1 300 Ωcm
at 15 °C. Your water utility company can give you
information about the specific water resistance.
Installation
■
Ensure the axial fit of the connection pipes in the
nozzles.
■
Tighten the union nuts on the nozzles with an
open-end wrench and counter hold with a suit-
able open-end wrench.
■
The T-piece (for the pressurised connection)
and flexible connection hose are available
commercially.
■
Only the approved unpressurised valves may be
used when connecting without pressure (Special
accessories: Single-lever mixer tap BZ13062,
Two handle fixture BZ13051).
■
Exchange the perlator from the tap fixture with
the supplied aerator to change the spray pattern
of the tap.
Controlling temperature
The supply temperature (probably lower in winter)
and pressure fluctuations can influence the tem-
perature of the water leaving the tap.
■
Turn the valve slowly in the closed direction for
higher temperatures (F1).
■
Add cold water for lower temperatures (F2).