24
en
After installation
DE05101, DE06101, DE06111, DE08101
and DE08111 (ixed electrical connection)
Switch on the fuses.
DE04101 and DE10104
Insert the plug into the mains socket.
■
First start-up
Initial rinsing
Open the warm water tap and allow water to
■
low for at least 1 minute (low-rate at least
2 litres per minute). Only then (for safety rea-
sons) will the appliance begin to heat.
Info:
The appliance will not heat if the dispensed
water low is interrupted prematurely. Open the
warm water tap again and allow water to low
for at least 1 minute.
Tip:
Should the appliance not start because of a
reduced low-rate, remove the perlator, aerator or
similar before starting and repeating the process.
Important:
If the continuous-low heater does not
have suficient water low due to low water line
pressure in your domestic plumbing system:
Switch off the circuit-breakers/fuses or remove
■
the mains plug.
Remove the low-rate limiter (
■
H1 – H4
).
Controlling temperature
The supply temperature (probably lower in winter)
and pressure luctuations can inluence the tem-
perature of the water leaving the tap (refer to igure
on page 22).
Turn the valve slowly in the closed direction for
■
higher temperatures (
F1
).
Add cold water for lower temperatures (
■
F2
).
Hand over the installation and operating instruc-
■
tions to the user and explain how the appliance
operates.
H2
H1
H3
H4
Important