7.4.3 Message Structure – Inverter to Control Device
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data Byte 2
Data Byte 1
Parameter Number
0 = Absolute Frequency
1 = Percentage Frequency
Toggle Bit
Unused
0 0 0 Parameter in bytes 7 & 8
1 0 1 Parameter limited
1 1 0 Parameter cannot be written
1 1 1 Invalid parameter
0 0 1 Current in bytes 7 & 8
0 1 0 Fault code in bytes 7 & 8
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data Byte 4
Data Byte 3
Actual Frequency
Absolute
0.0 to 400.0 Hz
Percentage 0.0 to 100.0% of maximum frequency