Siemens Energy & Automation
8-7
SIMOREG DC Master Base Drive Panel Operating Instructions
L1
L2
L3
E-STOP
START
STOP
SPEED
SETPOINT
(10K)
X174
2
4
5
1
P10
REF+
REF-
COM
34
X171
37
38
39
36
P24
RUN
ENABLE
SELECT INPUT
SELECT INPUT
P445 = 1
(PUSH-BUTTON CONTROL)
XS
106
105
ES/P24
E-STOP WHEN DE-ENERGIZED
26
27
28
29
30
31
X174
P15
COM
A
A
B
B
ENCODER
MOTOR
FIELD
460 VOLT
3 PHASE, 50 / 60 HZ.
A1(+)
A2(-)
80(+)
81(-)
CW
X300
Run Ready Fault
PMU
8.4.2 Configured with Analog Speed Setpoint and
Push-Button Start/Stop Control
P444 = 16
(OFF 1 WHEN DE-ENERGIZED)